SR-125079 · Issue 187143

Fixed HTML title error in tooltip

Resolved in Pega Version 7.1.8

The tooltip of the error icon on a tab in a tab group was showing as "null" in the HTML title attribute. This has been resolved by adding the data-taberror attr to the td with id = 'tabcontainer', which is used to find the title of an error element in js.

SR-125091 · Issue 187602

Corrected display issue for treegrid with Microsoft Internet Explorer 9

Resolved in Pega Version 7.1.8

Using the Microsoft Internet Explorer 9 browser, the first column in the treegrid was not visible until there was a refresh in any section of the grid. This was due to mishandling of the container ID, and has been fixed.

SR-125143 · Issue 187274

Length limits for form URLs

Resolved in Pega Version 7.1.8

When using the out-of-the-box Other Actions button, selecting 'Refresh' caused a blank page to display and resulted in an 'ERR_CONNECTION_RESET' script error. This happened when a form submit URL including all input parameters exceeded the max length expected. The submit function has been modified to send only the required params as part of the URL, and not all hidden inputs.

SR-125196 · Issue 191599

Variable added for non-English fonts in RTE

Resolved in Pega Version 7.1.8

Previously, the dropdown for font styles in pxRichTextEditor control contained only English-language fonts and did not include fonts for other languages such as Japanese. To enhance the localization, the global variable 'window.customCKEditorFonts' has been added to override 'CKEDITOR.config.font_names' when desired.

SR-125210 · Issue 189127

Customization corrected for RRHeader section of RD

Resolved in Pega Version 7.1.8

If the RRHeader section item was customized and renamed, opening Report Definition and clicking "Edit Report Title" did not produce the expected results even with the "Edit Report Title" command enabled. This was due to the RRHeader section being hard-coded; this is now loaded dynamically to allow for customization.

SR-125245 · Issue 187386

Search ability corrected for rule names containing spaces

Resolved in Pega Version 7.1.8

While a space was allowed in the rule name of a report category rule, searching for a rule name with a space generated the error "Unable to open instance Error: Can't find record". This was due to a missing JavaIdentifier validator for the "pyCategoryName" property in "Rule-Category" class, and this has been added.

SR-125254 · Issue 188703

Added Finish Assignment check for old harnesses

Resolved in Pega Version 7.1.8

After upgrade, a failing post flow action validation created the inability to correct the errors and resubmit using a pxButton which performed an out of the box "Finish Assignment." When trying to do so, a busy indicator was displayed and the application froze. This was caused by an incorrect legacy harness pointer for the Action section. A check for old harnesses has been added, and the submit API now sets the target of form submit for finish assignment to the parent window.

SR-125268 · Issue 188000

Added ownership check for DeleteModalHeader process

Resolved in Pega Version 7.1.8

When closing a modal dialog, the dropdown in the parent window became disabled and did not allow further selection. This was caused by the modal js throwing an error while attempting to remove an element that was not its child. To avoid this, the deleteModalHeader js API has bene modified to check the parent/child relationship before proceeding with the delete.

SR-125548 · Issue 195950

Corrected masking of screen by busy indicator

Resolved in Pega Version 7.1.8

Only a portion of the screen was being masked by the busy indicator, allowing modifications to be made on the other visible portions of the screen. This has been corrected.

SR-125568 · Issue 188832

Data transform checkbox handling fixed

Resolved in Pega Version 7.1.8

A data transform configured for 'Refresh When' on a section include property panel was not being executed. This was caused by the data transform checkbox not being honored properly inside the Refresh action.GenerateClientWhenDiv and picking the wrong child item. This has been fixed.