INC-147654 · Issue 642186

Updates to displaying embedded images in cases

Resolved in Pega Version 8.3.6

Sending an email with an embedded image to the email ID associated with the email listener successfully created the interaction case, but the embedded image was not displayed when the case was opened from the work-basket. A rule-not found exception was seen in the tracer for pyGetImageDisplay, the rule responsible for displaying the images in the ET pane. Investigation showed that when URLObfuscation was turned on, the decryption of the URL was not successful because "&" had been encoded to '& amp;'. This has been resolved by calling the activity pyGetImageForDisplay using URLMapping instead. An additional issue was seen with displaying images in the email interaction pane where the additional empty new lines moved the image outside the intended place. This was traced to a customization for the reply area which used the pyHighlightedMessage property and converted newlines to br tags even in HTML mode. To resolve this, pyHighlightedMessage has ben modified to convert newlines to br tags only if the mode is plain text.

INC-152776 · Issue 621243

Check added for HTML and linefeed combined in email

Resolved in Pega Version 8.3.6

In the Interaction right hand pane Email triage widget, additional line breaks were seen when displaying email message data that contained table tags. This was a missed use case for email which contains both HTML and '\n', which resulted in the system replacing '\n' with < / br >. This has been resolved by adding a check whether the content has HTML tags which will avoid the replacement.

INC-165188 · Issue 635774

Third-party links allowed to pass target attribute in anchor

Resolved in Pega Version 8.3.6

Attempting to connect to Docusign, a third party application, via Email in an interaction portal was not working, and the error "account.docusign.com refused to connect" appeared. This was caused by the HTML data being sanitized so the attribute 'target' was not allowed to pass and the application could not open in a new tab. To resolve this, an update has been made that will allow the target attribute for an anchor tag.

INC-154254 · Issue 632638

Correct Email Bot training text highlighted

Resolved in Pega Version 8.4.6

When a piece of text was selected and tagged against an entity while training the Email Bot, the entity selection was misplaced and partially covered the actual text selected. The incorrect selection was then carried forward to the training data spreadsheet. To resolve this, rule changes have been made that will update HTML entities to HTML encoded forms.

INC-175994 · Issue 667483

Removed redundant Microsoft Outlook email interaction chain

Resolved in Pega Version 8.4.6

When opening an email interaction case, the email editor user interface area showed the complete email chain of the email for every new message that came in related to the case. This was traced to the difference in the selectors that various email clients use to construct a response to an email with email history in it, and has been resolved by updating the selectors for Microsoft Outlook in pyRichTextEmailHistorySelector so no conversation is repeated when using that client.

INC-187031 · Issue 676245

Topic handling updated for behavior tab

Resolved in Pega Version 8.4.6

While submitting topics configured on the behavior tab of the chat channel, duplicate records were created and a null pointer exception was generated. Investigation showed this was due to a difference in Topic handling between the email channel and the chat channel in a modal window, and has been resolved.