Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-117827 · Issue 186000

Improved condition handling for complex harnesses

Resolved in Pega Version 7.1.8

If a Review Harness had multiple embedded tab sections with includes, a read-only condition in the parent section was not being honored in a sub-section if the 'when' condition became false. This happened when a SectionIncludeInCell RUF passed an unquoted null value as a 3rd argument while invoking stream reference, and has been resolved.

SR-117827 · Issue 183888

Improved condition handling for complex harnesses

Resolved in Pega Version 7.1.8

If a Review Harness had multiple embedded tab sections with includes, a read-only condition in the parent section was not being honored in a sub-section if the 'when' condition became false. This happened when a SectionIncludeInCell RUF passed an unquoted null value as a 3rd argument while invoking stream reference, and has been resolved.

SR-117931 · Issue 181714

Resolved clipboard conflict for obj-open-by-handle

Resolved in Pega Version 7.1.8

Doing an obj-open-by-handle or obj-open-by-handle/copy on work objects containing properties that reference data pages caused errors about non modifiable pxObjClass properties and non matching clipboard property modes. This was caused by a clipboard conflict, and has been addressed by handling the clipboard property as set value for feature property.

SR-118213 · Issue 184519

Refresh When' behavior fixed for portal tabs

Resolved in Pega Version 7.1.8

When a 'Refresh When' was active on a portal tab, the system would become unresponsive while trying to refresh it. This was caused by an incorrect element call resulting in a JavaScript error and has been corrected.

SR-118440 · Issue 178175

Sorting fixed for RD Repeat Grids with joined properties

Resolved in Pega Version 7.1.8

When sorting a Repeat Grid based on a Report Definition, if the user tries to sort on a property from a join then it would fail with the error 'Cannot get property information for: Assign-Worklist..' This was caused by ObjClass being missing for few elements of page list, and has been fixed. In addition, a check has been added to ensure proper handling in cases where Obj class is missing.

SR-118474 · Issue 182925

Corrected time zone mismatch in Report Browser

Resolved in Pega Version 7.1.8

If a server and an operator had different time zones set, reports that were scheduled through the report browser to run and deliver notifications to a list of recipients would run immediately if the schedule was modified. To handle this time zone difference, "Pega-ScheduledTask.pzPostProcess" has been modified to use the time zone from calendar in the formatter.

SR-118474 · Issue 178295

Corrected time zone mismatch in Report Browser

Resolved in Pega Version 7.1.8

If a server and an operator had different time zones set, reports that were scheduled through the report browser to run and deliver notifications to a list of recipients would run immediately if the schedule was modified. To handle this time zone difference, "Pega-ScheduledTask.pzPostProcess" has been modified to use the time zone from calendar in the formatter.

SR-118602 · Issue 178489

Corrected flow action dropdown execution

Resolved in Pega Version 7.1.8

For certain work objects, selecting a flow action from the pyAction area resulted in an error message and the flow action did not execute. A sample error message might be "The FlowAction ... could not be added to this assignment." This was caused by a flaw in the code which assumed that simple integer IDs in the DOM are unique. The code that handles 'Take Action' input has been re-factored to be more robust.

SR-118755 · Issue 177568

Enhanced logging for access group decisions

Resolved in Pega Version 7.1.8

In order to facilitate troubleshooting, logging has been added to track how the Core Engine decides what Access Group to assign to the running Agent. This lists the name/ruleset/ruleset version of the Data-Agent-Queue record being utilized, the Access Group specified by it, and any further steps that determine what AG gets used. If the DAQ gets rebuilt, it will show how it gets rebuilt from the Rule-Agent-Queue record.

SR-118827 · Issue 179258

Work object reloading added to SFA portals

Resolved in Pega Version 7.1.8

When a work object in an SFA default portal (such as SFA SalesManager and SFAAdministrator) was opened by multiple users, modifications made by one were not seen by the other unless the other completely logged out and back in again. This was a function of the way the work object was opened and held in a thread, and has been modified with an API to reload the work object each time it is opened so that any saved changes are immediately available.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us