SR-D85111 · Issue 549196
Paging method updated for Select All in Broken Queue
Resolved in Pega Version 8.3.3
After clicking the 'Select All' box in Broken Queue In Admin Studio, scrolling up and down rapidly caused the checkboxes to be unselected. This was traced to the use of progressing paging in this scenario, and has been resolved by removing progressive paging and replacing it with the out of the box '1 of X' paging method.
SR-D87671 · Issue 547572
PegaCESvcsIntegrator security updated
Resolved in Pega Version 8.3.3
Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.
SR-D87673 · Issue 548626
PegaCESvcsIntegrator security updated
Resolved in Pega Version 8.3.3
Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.
SR-D90520 · Issue 552017
REST parameters updated for SauceLabs compatibility
Resolved in Pega Version 8.3.3
After configuring a call to SauceLabs testing through Deployment manager, the REST call was timing out. Investigation traced the issue to SauceLabs changing its parameter name from "browser" to "browsername", and the Pega parameter names have now been updated to reflect that change.
SR-D79397 · Issue 546415
Rule-Utility-Function references updated with library information
Resolved in Pega Version 8.3.3
The "changeSystemName” operation failed. This was traced to the function “getLocalizedValue” (Rule-Utility-Function) being saved into the PegaFS library due to runtime resolution based on the function signature even though the actual Rule-Utility-Function from “Pega-Rules” ruleset needed to be picked in this case. To ensure the correct ruleset is picked, Rule-Utility-Function references have been updated with library information to resolve the resolution collision scenario.
SR-D80539 · Issue 544793
Testcases are not available for 'access when' rules
Resolved in Pega Version 8.3.3
Attempting to create test cases for access when rules resulted in guardrail warnings about the need to create a test case. Because Test Cases are not available for the Access When rule type as per Pega expected behavior, the guardrail warnings are not valid and have been removed.
SR-D88451 · Issue 550847
Testcases are not available for 'access when' rules
Resolved in Pega Version 8.3.3
Attempting to create test cases for access when rules resulted in guardrail warnings about the need to create a test case. Because Test Cases are not available for the Access When rule type as per Pega expected behavior, the guardrail warnings are not valid and have been removed.
SR-D86011 · Issue 548152
Browser fingerprint validation issue resolved
Resolved in Pega Version 8.3.3
After upgrade, Pega logoff was happening automatically within five minutes while using Microsoft Internet Explorer. This was traced to the COSMOS-based portal in Microsoft Internet Explorer 11 generating different hashes for different parts of the screen, causing a "Browser fingerprint validation failed" error because of the pzBFP token mismatch. To resolve this, an update has been made to exclude the graphic components for calculation of browserfingerprint.
SR-D96395 · Issue 555117
CDK key loading modified for better database compatibility
Resolved in Pega Version 8.3.3
Users were unable to log on to the system and received the error "There has been an issue; please consult your system administrator." Investigation showed the log errors stating "(dataencryption.DataKeyProvider) ERROR localhost - Could not get CDK from systemKeyManagementCache - System CDK is null". This was an issue specific to the MS SQL Server database when there were 6 or more CDKs in the database: CDK keys are loaded from database into Cache using an SQL statement which had the ORDER clause. By default, the ORDER clause treats NULL values differently on different databases, and this caused MS SQL databases to not load a necessary CDK key. To resolve this, the SQL query has been modified so the result will be the same for all supported daatbases (Oracle, Postgres & MS SQL Server).
SR-D79181 · Issue 551123
OKTA receives parameters on logout
Resolved in Pega Version 8.3.3
When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the database, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.