SR-A90493 · Issue 258125
Connect-Wait made more robust for timeouts and multiple calls
Resolved in Pega Version 7.2.2
To check an asynchronous thread running for a long time, a connect-wait was given multiple checks for the same pool id. On first execution of this connect-wait, it was unexpectedly timing out before hitting the timeout settings in the parameter. For all of the subsequent calls to connect-wait, it was waiting for the asynchronous thread to complete, i.e. exceeding the timeout limit. Normally Connect-Wait is called once and the wait time defaults to the point where data page load finishes. In this particular use case, when connect-wait hit the timeout due to a user-specified value, the system considered it an error state and cleaned up the pool ID from the thread. The subsequent waits were failing due to the mapping for the pool ID being removed when first Connect-Wait call ended with timeout. To support this use, better handling has been added for the user-specified timeout, and the system will not clear the mapping for the pool ID if Connect-Wait ended due to timeout. In cases where another Connect-Wait request does not come, the mapping will be cleared when the thread terminates.
SR-A15970 · Issue 249633
Data population clipboard updated to handle mixed copy type
Resolved in Pega Version 7.2.2
Trying to load the auto populate property 'Address' with a data page was not working due to a Ref-Type AP that was present inside a Copy-Type AP. This was found to be a flaw where all the pages in the subtree of the copy type AP have a special java status set, whereas the property elements have the special java status unset, causing the Ref-type AP inside copy-type AP to fail to populate. The data population clipboard functions have been updated to handle this case.
SR-A101848 · Issue 270084
Obj-Browse accepts Embedded Code-Pega-List
Resolved in Pega Version 7.2.2
Trying to reference a Property of Page Code-Pega-List in an activity using Obj-Method activity generated an error when executing, indicating that an invalid page name was passed. However, according to the Obj-Browse method help screen, there is no restriction on whether this page has to be top-level or embedded. After analysis it was determined that the code did not previously allow embedded pages in obj-browse, and this has been added to support this use.
SR-A100617 · Issue 267626
Typos corrected in SQL error
Resolved in Pega Version 7.2.2
Typographical errors have been corrected in the message generated by a pzInsKey SQL error.
SR-A26298 · Issue 249983
Corrected JNDI name mismatch on node quiescence
Resolved in Pega Version 7.2.2
When a JBoss HA environment attempted to quiesce a node where the JNDI name used for PRAdapter Connection factory was different in the RAClient.java and ear properties due to reference shortcuts, a JNDI name not found exception was logged and the node never entered a full quiesced state. To resolve this, the system will now ensure the JNDI name is referenced with full context.
SR-A26298 · Issue 250821
Corrected JNDI name mismatch on node quiescence
Resolved in Pega Version 7.2.2
When a JBoss HA environment attempted to quiesce a node where the JNDI name used for PRAdapter Connection factory was different in the RAClient.java and ear properties due to reference shortcuts, a JNDI name not found exception was logged and the node never entered a full quiesced state. To resolve this, the system will now ensure the JNDI name is referenced with full context.
SR-A91839 · Issue 259235
Resolved ConcurrentModificationException in mContent iteration
Resolved in Pega Version 7.2.2
When adding or removing the items from a repeat grid and submitting the modal dialog, an intermittent ConcurrentModificationException was coming from the API ClipboardPageImpl.clearMessages(). This was traced to the function iterating over mContent and has been fixed by making a copy of mContent and iterating over that.
SR-A92219 · Issue 259481
XSD file contains classes extracted with -c flag
Resolved in Pega Version 7.2.2
When executing a BIX extract to XML using the -c flag, the XML file contained outer tags but the corresponding XSD file did not. This has been corrected.
SR-A93386 · Issue 262694
Header close added to enable proper load balancing
Resolved in Pega Version 7.2.2
When F5 was being used as a load balancer and the intention was to stop new connections before quiescing a node, sending a browser request between quiesce complete and node stoppage generated an HTTP 500 error on the first submission to the server after quiesce. Work could continue after this error. This issue was due to the system properly redirecting and invalidating the cookie but not closing the HTTP 1.1 connection session afterwards, resulting in the load balancer not properly rebalancing requests within the same HTTP 1.1 connection. F5 load balancer has a configuration which directs the node not to send new http requests to a quiesced node, but this confusion caused the existing connections to still be routed to old node. This has been fixed with the addition of an explicit Connection: Close Header as a 303 redirect so the load balancers will trigger a rebalance properly.
SR-A24414 · Issue 260410
Flexibility added for ruleset persistence with dynamic locale
Resolved in Pega Version 7.2.2
When launching an intent in CS, the content sporadically failed to localize all or part the content until the browser was refreshed and the task re-entered. This was caused by a configuration that was trying to set the locale dynamically, an unsupported function. To better support flexibility, changes have been made to honor the current Ruleset List instead of the default Ruleset List so that even if the locale changed dynamically, the changed rulesets will be persisted.