INC-139095 · Issue 596508
Portal loads for Simplified Chinese locale in Microsoft Internet Explorer
Resolved in Pega Version 8.2.8
When using Microsoft Internet Explorer, the portal would not load when using the Simplified Chinese locale. This was caused by Microsoft Internet Explorer rendering the locale as 'zh-CN-#Hans' instead of the expected 'zh-cn'. This has been resolved by adding a check to remove the "#" in the locale string to avoid a malformed URL.
INC-139260 · Issue 592216
Handling added for third party form library
Resolved in Pega Version 8.2.8
When using a third party library which created a form tag, the wrong form was used on submit in the Ajax container. This has been resolved by updating the pzpega_ui_doc_submit file submitInner method to handle this use case.
INC-140289 · Issue 589001
Check added to preserve clipboard pages for pop-up
Resolved in Pega Version 8.2.8
Many properties were missing in the clipboard after launching an ImageViewer. This was traced to the clipboard pages being deleted in the pop-up mode, and has been resolved by adding a check to not delete pages in case of pop-up opened from top navigation case.
INC-142589 · Issue 595492
Corrected tooltip evaluation for multiselect
Resolved in Pega Version 8.2.8
After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.
INC-143260 · Issue 599304
Overlapping columns fixed in ReportViewer
Resolved in Pega Version 8.2.8
When Report Viewer was used for Report Definition, displaying it on dashboard columns resulted in columns that overlapped each other. This was traced to a resize issue related to the scrolling checkbox and has been resolved.
INC-147794 · Issue 602702
Entity relation diagrams UI corrected
Resolved in Pega Version 8.2.8
After upgrade, attempting to create a campaign showed a blank page. This was traced to the Entity relationship diagram not loading, and has been resolved by adding a safe check.
SR-D91344 · Issue 560624
Resolved PageCannotBeSerializedForPassivationException in logs
Resolved in Pega Version 8.2.8
The exception "One or more properties could not be serialized during passivation and have therefore been lost. They will not be available on activation. Please ensure that all property data is Serializable" was observed in the logs. Investigation showed there was an HTML fragment in 'pzGridOpenAction' that was adding non-serializable properties to the clip board. This did not cause a functional issue, but has been resolved by modifying the way the system obtains and reuses the class definition.
SR-D96909 · Issue 558139
Removed extra scroll bar in Multiselect
Resolved in Pega Version 8.2.8
An extra scroll bar was appearing when opening the multi-select control case manager portal using the "Results displayed Maximum 500 results to display" setting. This was a result of recent updates to the popover scroll and height that caused on overflow condition. To resolve this, the logic for Multiselect has been updated.
SR-D44942 · Issue 518354
Guided tour popups handling added for right-to-left language locales
Resolved in Pega Version 8.2.6
Guided Tour Popups were still appearing in the default EN location after switching to the ar_AR locale. This was traced to a missed use case for locales using a right-to-left mode such as Arabic or Hebrew, and has been resolved by updating the guided tour engine openPopOver function to account for the HTML tag dir attribute for value of "rtl". This will anchor the pop over to rightBottom / and display the arrow on the rightTop instead of leftBottom / leftTop.
SR-D52138 · Issue 537505
Property setting corrected for On Join and Exclusion shapes in Expression Builder
Resolved in Pega Version 8.2.6
The properties for the defined page did not appear when using the type-ahead feature to select properties for the On Data Join and Exclusion shapes in Expression Builder. This was an issue related to the property being referenced for setting the context in the expression builder, and has been corrected.