INC-125803 · Issue 568661
Cross-site scripting updated on activities
Resolved in Pega Version 8.1.9
Additional Cross-site scripting work has been done on activities.
INC-127981 · Issue 563000
Rulesets removed from direct invocation ability
Resolved in Pega Version 8.1.9
Internal rules have been updated so that they are no longer available to be invoked directly by a client or service.
INC-146837 · Issue 602673
PerformCriteria contains CurUserHasRequiredSkills 'when' rule
Resolved in Pega Version 8.1.9
A customer version of the PerformCriteria data transform was generating a validation error due to a qualified statement that resulted in a null result. This has been resolved by updating the PerformCriteria DT to include the CurUserHasRequiredSkills 'when' rule.
SR-D65866 · Issue 536427
Corrected approval step task message
Resolved in Pega Version 8.1.9
When a case progressed to the approval step, the task name did not properly appear as part of the "Please approve or reject this" message. In another scenario, a portal which supported locale switching was not translating "Please approve or reject this" when the locale was switched, but instead displayed the message in the original language. Investigation traced this to the pzInstructionsForApproval data transform storing the localized field value, causing it to persist inappropriately. This has been resolved.
INC-121444 · Issue 561810
Added handling to force text area maxlength in Microsoft Edge
Resolved in Pega Version 8.1.9
When using the Microsoft Edge browser, it was possible to continue entering characters in excess of the value set for the 'max characters' property. Investigation showed that the Microsoft Edge browser does not honor the maxlength attribute on text area; to resolve this, logic has been added to restrict the user from entering extra characters above the max limit.
INC-125334 · Issue 581939
Focus persists for embedded Tab Group layout with section refresh
Resolved in Pega Version 8.1.9
When a Tab Group Layout was configured with multiple sections using multiple input elements including one with a 'Refresh this section' action, using the Tab key to reach the input element, make a change, and hit Tab again caused the focus to reset to the top input element. This has been corrected.
INC-125398 · Issue 564978
Updated handling for checkboxes configured in the header
Resolved in Pega Version 8.1.9
After configuring multiple checkboxes where each checkbox had a different property and different DT as action set and then using them as a single column header in the table, the on-change of any one checkbox caused all of the checkboxes to be checked or unchecked in the column header. This was caused by the pega.ui.grid.prototype.checkAllIfInHeader, which selects or unselects all checkboxes present in table (header +. body) based on checkbox status in header. However, the header row should not be part of the iterator during this function, and the necessary update has been made.
INC-126255 · Issue 580910
Resolved "maximum limit for pending changes" error
Resolved in Pega Version 8.1.9
When attempting to create a work object in a custom way using doCreateNewCase from the Smart investigate layer by using the RMButtonWithoughtWorkCaseNGP section, a popup showed the error “You have reached maximum limit for pending changes. Please commit/cancel one or more changes to continue.” The error did not occur when creating the case using the out-of-the-box Create New Work action. This was traced to the custom configuration creating work object threads that were not destroyed after the work item is closed. To resolve this, handling has been updated for passing dynamiccontainerID and contentID parameters for OpenWorkByURL case. Note that the pzUpdateActionInfo activity must be called in any custom activity before the actual activity is invoked.
INC-126432 · Issue 564625
Support added for resuming scenario test recording
Resolved in Pega Version 8.1.9
When running an automation recording, a refresh of the harness was hiding the recording panel. When it was reopened, the panel was not responsive but the recording process was still running. This was traced to a scenario where the portal harness had a second harness running on it (such as a normal case worker would have) and the "Render As Single Page" was not checked: clicking a button with an action like "create new work" caused the whole harness (top) to be refreshed, resulting in the panel issues. To resolve this an enhancement has been added which will maintain the Scenario test recording when browser refresh happens, and recording can be restarted by clicking the toolbar option.
INC-127201 · Issue 562822
Thread Cleanup error resolved
Resolved in Pega Version 8.1.9
After upgrade, intermittent exception errors were being generated by the FreeClipboard activity when switching between applications. This was traced to specific use-case issues with Thread Cleanup, and has been resolved.