INC-160275 · Issue 628103

Unchecked Include descendant classes in pyFeedUserDetails report definition

Resolved in Pega Version 8.6

After upgrade from Pega 7.4. to Pega 8.4, the use of a custom class 'XX-Data-OperatorLoginDetails' which pattern-inherits from Data-Admin-Operator-ID was causing the error "Union not applied because properties [pyImageFileName, pyEmailAddress, pyUseLocale, pyDefaultTimeZone] are not optimized in Data-OperatorLoginDetails”. This happened when the case manager portal was launched and the report definition pyFeedUserDetails (introduced in newer releases) was running by default, and was due to the presence of a few unoptimized properties when the report definition had "Report on Descendant classes" - include all descendant classes, checked by default. To resolve this, the checkbox to Include descendant classes in pyFeedUserDetails is now set as unchecked by default.

INC-160295 · Issue 635008

Null check added for pzinskey in CSLoadSelectedArticle

Resolved in Pega Version 8.6

In step 5 of CSLoadSelectedArticle, there is a call to pzGetAssociatedTags. Step 1 of pzGetAssociatedTags is an Obj-Browse with MaxRecords set to 100000000, and there is logic to retrieve records where pxLinkedRefFrom = Primary.pzInsKey. If Primary.pzInsKey is null, then the Obj-Browse will fetch all of the records. In order to prevent an unnecessary flood of results, a when condition has been added in the CSLoadSelectedArticle rule to check pzInskey so that when the context is empty the system will not call the pzGetAssociatedTags and return the entire record set.

INC-160851 · Issue 631620

Multiple Pulse attachments deleted correctly from datapage

Resolved in Pega Version 8.6

If a Pulse post had only one attachment, removing the post using the Delete option correctly deleted the attachment from Link-attachment and Data-WorkAttach-File. However, if more than one attachment was present, the attachments were removed from view in the UI but were not deleted as expected from the datapage D_AttachmentList. This caused the pr_data_file table to grow very large. Investigation traced the issue to a 'when' condition in the PegaSocial-Message-ValidateDelete activity that was incorrectly being set to true due to a null value and causing the system to skip the deletefile step. This has been resolved by updating the logic to correctly handle removing multiple attachments on delete of a post.

SR-D72141 · Issue 542661

Approved flow rule image unlocked

Resolved in Pega Version 8.3.3

When the Approval Required check box was enabled for rulesets (i.e another person with access to this work queue should approve changes to the rules), a rule which was approved was unlocked and moved back to the original ruleset as expected, but the binary image associated with the flow rule remained locked and any other user other than the one who previously checked in the rule was denied access with a "check out failed" error. This locking error has been resolved by modifying the Rule-Obj-Flow!CleanUp activity to set Param.IgnoreInstanceLockedBy = true.

SR-D90544 · Issue 550371

Corrected row focus for deleting in App Studio case model

Resolved in Pega Version 8.3.3

When attempting to delete a row of properties from the 2nd page of the data model of a case type while using App Studio, clicking on the delete icon brought up a dialog box asking for confirmation for deletion but at the same time the screen went back to the first page of the data model instead of remaining on the second page. Because of this, clicking on the OK button to confirm the deletion caused a random property from the first page to be deleted instead of the targeted row of the second page as expected. This was due to the refresh being triggered immediately within overlay UI actions, and has been resolved by updating the first trash icon action set for the section pzExpressFieldActions to be a modal instead of an overlay when launching local action.

SR-D76492 · Issue 549968

Added check for test case creation when cross-site scripting security enabled

Resolved in Pega Version 8.3.3

Test case creation was failing. Investigation showed that when the "Cross-Site Request Forgery" security setting was enabled, the CSRF token and Browser fingerprint were not included in AJAX calls, and the Ruleinskey was not getting passed. This has been resolved by adding a check to evaluate whether security measures are included or not when making a server call from AJAX, and including the tokens required when appropriate.

SR-D78467 · Issue 542317

Component rule check added to suppress unnecessary guardrail warnings

Resolved in Pega Version 8.3.3

After creating a component application using Configure > Application > Components, guardrail warnings were seen when saving the component. The component application allowed adding rulesets or other applications, but did not have all the tabs found in a normal application, so there was no option for adding the associated classes to define the UI class, Integration class and data class in the component application. As component is mostly a part of (or embedded inside) an application, this function was not given options to justify or suppress guardrail warnings like Rule-Application. To resolve this, a check has been added for component rule before generating guardrail warnings for Empty UI page, Empty Integration class, and Empty Data class.

SR-D85111 · Issue 549196

Paging method updated for Select All in Broken Queue

Resolved in Pega Version 8.3.3

After clicking the 'Select All' box in Broken Queue In Admin Studio, scrolling up and down rapidly caused the checkboxes to be unselected. This was traced to the use of progressing paging in this scenario, and has been resolved by removing progressive paging and replacing it with the out of the box '1 of X' paging method.

SR-D87671 · Issue 547572

PegaCESvcsIntegrator security updated

Resolved in Pega Version 8.3.3

Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.

SR-D87673 · Issue 548626

PegaCESvcsIntegrator security updated

Resolved in Pega Version 8.3.3

Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.