Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-163970 · Issue 636136

Expression Builder updated for special character handling

Resolved in Pega Version 8.6

If a modulo operator (%) was used in expression builder, the expression showed the correct value when it was submitted (closed) but on reopen the expression was changed and not calculated correctly. If the expression was not reopened then it calculated the value properly. This issue was traced to a server call to pzEvaluatePegaExpression which treated certain values as containing special characters, and has been resolved by updating the handling for this scenario.

INC-164944 · Issue 636291

Logic updated to handle decision trees over 64k

Resolved in Pega Version 8.6

An exception was thrown when decision trees reached the 64K size limit. This has been resolved by modifying the logic in the DecisiontableMethodBody Rule-Utility-Function where the split size nPropRowLimit is based on the number of columns.

INC-127981 · Issue 562998

Rulesets removed from direct invocation ability

Resolved in Pega Version 8.2.7

The following rules have been updated such that they are no longer available to be invoked directly by a client or service: Clipboard_ExecuteActivity, getClassInstances, getOperatorIDs, and GetXMLRuleData. In addition, pzAutoGenClipboard_ExecuteActivity will now require authentication.

SR-D79831 · Issue 562800

Access Deny working as expected for Offers

Resolved in Pega Version 8.2.7

It was possible to Save-As an offer in PegaMKT-Work-Offer after encountering an access deny rule. The record was not created in Dev Studio, however, and an expected denial of access was not registered at runtime. This was due to Access deny rules not being considered as a part of validation, and has been resolved by adding the necessary permission validation to the new harness that will produce the error message informing the user that they are missing a permission. Additional work has also been done to pass the 'pzKeepPageMessages' parameter as true so that page level error messages are correctly displayed.

SR-D87673 · Issue 548627

PegaCESvcsIntegrator security updated

Resolved in Pega Version 8.2.7

Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.

SR-D88451 · Issue 550848

Testcases are not available for 'access when' rules

Resolved in Pega Version 8.2.7

Attempting to create test cases for access when rules resulted in guardrail warnings about the need to create a test case. Because Test Cases are not available for the Access When rule type as per Pega expected behavior, the guardrail warnings are not valid and have been removed.

SR-D91834 · Issue 554424

Related cases of different types properly linked in Case Worker Portal

Resolved in Pega Version 8.2.7

After creating a case of type1 in the Case Worker portal, creating a case of type2 from the first case showed the case ID of the second case in the Related Work section as expected. However, after clicking on the link of the case ID of the second case from the related work section, the second case opened but the case ID of the first case was not shown in the Related work. The cases were correctly associated when the Case Manager portal was used instead. This was traced to the Case Worker clipboard continuing to hold the previous case ID thread, and has been resolved.