INC-127981 · Issue 562998

Rulesets removed from direct invocation ability

Resolved in Pega Version 8.2.7

The following rules have been updated such that they are no longer available to be invoked directly by a client or service: Clipboard_ExecuteActivity, getClassInstances, getOperatorIDs, and GetXMLRuleData. In addition, pzAutoGenClipboard_ExecuteActivity will now require authentication.

SR-D79831 · Issue 562800

Access Deny working as expected for Offers

Resolved in Pega Version 8.2.7

It was possible to Save-As an offer in PegaMKT-Work-Offer after encountering an access deny rule. The record was not created in Dev Studio, however, and an expected denial of access was not registered at runtime. This was due to Access deny rules not being considered as a part of validation, and has been resolved by adding the necessary permission validation to the new harness that will produce the error message informing the user that they are missing a permission. Additional work has also been done to pass the 'pzKeepPageMessages' parameter as true so that page level error messages are correctly displayed.

SR-D87673 · Issue 548627

PegaCESvcsIntegrator security updated

Resolved in Pega Version 8.2.7

Security updates have been made which now require authentication to consume the services from the PegaCESvcsIntegrator package.

SR-D88451 · Issue 550848

Testcases are not available for 'access when' rules

Resolved in Pega Version 8.2.7

Attempting to create test cases for access when rules resulted in guardrail warnings about the need to create a test case. Because Test Cases are not available for the Access When rule type as per Pega expected behavior, the guardrail warnings are not valid and have been removed.

SR-D91834 · Issue 554424

Related cases of different types properly linked in Case Worker Portal

Resolved in Pega Version 8.2.7

After creating a case of type1 in the Case Worker portal, creating a case of type2 from the first case showed the case ID of the second case in the Related Work section as expected. However, after clicking on the link of the case ID of the second case from the related work section, the second case opened but the case ID of the first case was not shown in the Related work. The cases were correctly associated when the Case Manager portal was used instead. This was traced to the Case Worker clipboard continuing to hold the previous case ID thread, and has been resolved.

SR-132987 · Issue 205014

Enhanced Expression Builder icon availability

Resolved in Pega Version 7.1.9

Previously, the Expression Builder gear icon was only available for text type properties: this has been updated to make the EB icon visible for all property types.

SR-133079 · Issue 202877

Repaired column header labels in Decision Table

Resolved in Pega Version 7.1.9

Clicking on a column header and opening the property changer, then closing it using the X in the top-right corner of the popup caused the label to change to the label of the rightmost column. This was traced to incorrect behavior by the modal dialog where closing the window did not return the correct value from the previous launch. This has been corrected.

SR-133382 · Issue 205956

Updated paragraph styles in Security policy

Resolved in Pega Version 7.1.9

Using ie, the History tab and Policy Definition tab had incorrect content while viewing Security policy rules. This was found to be an issue with the styles present in the paragraph rule 'pzScriptSrcDescription', and the styles have now been updated.

SR-133382 · Issue 205957

Updated paragraph styles in Security policy

Resolved in Pega Version 7.1.9

Using ie, the History tab and Policy Definition tab had incorrect content while viewing Security policy rules. This was found to be an issue with the styles present in the paragraph rule 'pzScriptSrcDescription', and the styles have now been updated.

SR-133538 · Issue 205317

Smart Prompt fixed for DT column headers

Resolved in Pega Version 7.1.9

Smart Prompt was not working when configuring Decision Table column headers. The Decision table rule (including the smart prompt control and pages&classes tab) was updated as part of rule form conversion from form-based to harness-based. However, the smart prompt is loaded in a separate frame and did not have the necessary access to the decision table rule which contained page&classes values. While there was a workaround of manually typing in and saving the 'page.propertyname', this has been corrected.