INC-176542 · Issue 668477
Removed unused function to improve Class rule save performance
Resolved in Pega Version 8.6.2
Clicking save on the Policy Class rule was not working correctly or was taking an excessive amount of time to respond. Adding property mapping in the External Mapping tab of the Class rule exhibited the same behavior. Investigation showed there was an infinite loop being invoked in the class ruleform, which was traced to the disableKeyEntries() function. As this function is no longer used, this has been resolved by updating the RF_RuleObjClassScript.js to remove disableKeyEntries and any function calls to it.
INC-179111 · Issue 666017
Toolbar delete handling modified
Resolved in Pega Version 8.6.2
After upgrade from Pega 7.4 to 8.5, the toolbar delete button behavior was different. Previously, the pzRuleFormToolbarDeleteRule section rule invoked RuleFormMain on refresh, but the updated version was calling RuleFormHeader, preventing the deletion of the assignment from the class instance. This was an unanticipated edge case and has been resolved by updating the action in the button to refresh the section RuleformMain instead of header.
INC-180468 · Issue 659923
JAWS correctly reads work group header
Resolved in Pega Version 8.6.2
While creating the groups within the organizational unit, JAWS was reading the name of the frame as "Process Work Area" instead of "Create Work Group" and "enter data" instead of the name of the edit field with edit instructions. This has been resolved by adding a property to the short description label so it contains the instance type that is being created.
INC-182150 · Issue 669852
DSS added to control Pega Version Banner
Resolved in Pega Version 8.6.2
Nuisance errors were being logged related to the application trying to connect to Pega to confirm available versions. This has been resolved by adding the 'when' rule pyShowVersionBanner to pzStudioHomeWrapper which allows disabling/enabling the Version Banner based on the setting used in the DSS ShowVersionBanner. pyShowVersionBanner defaults to true when DSS ShowVersionBanner does not exist.
SR-132987 · Issue 205014
Enhanced Expression Builder icon availability
Resolved in Pega Version 7.1.9
Previously, the Expression Builder gear icon was only available for text type properties: this has been updated to make the EB icon visible for all property types.
SR-133079 · Issue 202877
Repaired column header labels in Decision Table
Resolved in Pega Version 7.1.9
Clicking on a column header and opening the property changer, then closing it using the X in the top-right corner of the popup caused the label to change to the label of the rightmost column. This was traced to incorrect behavior by the modal dialog where closing the window did not return the correct value from the previous launch. This has been corrected.
SR-133382 · Issue 205956
Updated paragraph styles in Security policy
Resolved in Pega Version 7.1.9
Using ie, the History tab and Policy Definition tab had incorrect content while viewing Security policy rules. This was found to be an issue with the styles present in the paragraph rule 'pzScriptSrcDescription', and the styles have now been updated.
SR-133382 · Issue 205957
Updated paragraph styles in Security policy
Resolved in Pega Version 7.1.9
Using ie, the History tab and Policy Definition tab had incorrect content while viewing Security policy rules. This was found to be an issue with the styles present in the paragraph rule 'pzScriptSrcDescription', and the styles have now been updated.
SR-133538 · Issue 205317
Smart Prompt fixed for DT column headers
Resolved in Pega Version 7.1.9
Smart Prompt was not working when configuring Decision Table column headers. The Decision table rule (including the smart prompt control and pages&classes tab) was updated as part of rule form conversion from form-based to harness-based. However, the smart prompt is loaded in a separate frame and did not have the necessary access to the decision table rule which contained page&classes values. While there was a workaround of manually typing in and saving the 'page.propertyname', this has been corrected.
SR-133538 · Issue 204972
Smart Prompt fixed for DT column headers
Resolved in Pega Version 7.1.9
Smart Prompt was not working when configuring Decision Table column headers. The Decision table rule (including the smart prompt control and pages&classes tab) was updated as part of rule form conversion from form-based to harness-based. However, the smart prompt is loaded in a separate frame and did not have the necessary access to the decision table rule which contained page&classes values. While there was a workaround of manually typing in and saving the 'page.propertyname', this has been corrected.