INC-142589 · Issue 595489
Corrected tooltip evaluation for multiselect
Resolved in Pega Version 8.4.3
After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.
INC-142714 · Issue 596554
Recent Cases from different applications available to open
Resolved in Pega Version 8.4.3
An enhancement has been added which will allow opening other application assignments in the Recent Cases section of the current application when the user has access to multiple applications.
INC-143005 · Issue 596954
Fluid Overlay displays as expected in Firefox
Resolved in Pega Version 8.4.3
After upgrade, using the Overlay format "Fluid" to perform the screening matches task in CLM using Firefox had an overlay that covered the entire screen but was missing the scrollbar to manage the content. This has been resolved by adding changes to support dynamic content (with scrollbar) for center overlay.
INC-119669 · Issue 562588
Special character handling added to filters for table sourced with parameterized RD
Resolved in Pega Version 8.1.9
Filters were not working on a table when sourced with a report definition which accepted a parameter value containing special characters (Eg: S&P). This has been resolved by using StringUtils.reversibleCrossScriptingFilter in the pzGetGridColUniqueValues activity to allow filters to contain special characters.
INC-145810 · Issue 599463
BIX log shows correct corrupted BLOB pzInskey
Resolved in Pega Version 8.1.9
An update has ben made to ensure the correct inskey is shown in the BIX logs for a corrupted BLOB.
SR-D90400 · Issue 563187
Explicit parent added for descendants in subreport to correct summary
Resolved in Pega Version 8.1.9
When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.
INC-130304 · Issue 567924
Retry logic added for downloading upgraded rules
Resolved in Pega Version 8.1.9
A Rules upgrade failed while downloading applications from the maintenance server due to an SFTP server connection failure. This has been resolved by adding logic to retry if the first connection attempt fails.
INC-130695 · Issue 587659
Enhancements for upgrading in multi-tenant environment
Resolved in Pega Version 8.1.9
Some muti-tenant installations use the same applications or rule instances with the same pzInsKeys for different tenants. This can cause upgrades to time out due to the system fetching all pzInsKeys (which will have duplicates) and working with them in a default batch size of 500 each over 4 threads. This led to the same keys potentially being allocated and processed in different threads, resulting in duplicate processing and timeouts. This has been resolved by updating the select query to fetch the tentantid and pzInskeys in the MT system to avoid duplicate work in multiple threads. In addition, running Generate Declarative indexes fetches the pzinskeys and generates indexes for each record, but before generating, the existing index for the record is deleted and then inserted. Because the delete query to generate the index was not tenant aware, all of the records for the key were deleted for the tenants for that key, but the new index was created only in one tenant. This has been resolved by enhancing the DELETE query to be tenant aware, which will avoid deleting the indexes for all the tenants given an index key.
INC-132218 · Issue 573359
Resolved buffer overflow for Migration loadDatabase
Resolved in Pega Version 8.1.9
A Rules upgrade failed in the Migration step at loadDatabase stage, involving the move of all the table records from old schema to new schema. This was traced to the inability of Migration to load blob of sizes more than 100 MB, and has been resolved by updating Migration to use byte[] to read the blob content with the help of metadata that contains blob length.
INC-133202 · Issue 574701
TableRenameUtil hashing improved
Resolved in Pega Version 8.1.9
During index name generation, the algorithm that was responsible for index name uniqueness was sometimes insufficient and cerated a loop condition. This has been resolved by using a stronger hash algorithm and refactoring the code that could result in a loop.