Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-132135 · Issue 202410

Smoothed 'save as' for private reports without checkout privs

Resolved in Pega Version 7.1.8

When a user did not have checkout option either at the operator level or at the design time rule-set level, trying to use 'Save As' on Report definition rules reports in Private category resulted in an error but actually saved the report at the back end. Opening the Case Manager portal and trying to do a 'save as' of an existing report led to the report category being populated as private but the standard categories got populated in the drop down. If OK was clicked, then the standard categories were replaced with private category. To improve this, a check has been added to detect a non-developer operator, who is then allowed to save in their personal category.

SR-132538 · Issue 201237

Updated RD handling for WorkBasketAssignments

Resolved in Pega Version 7.1.8

After upgrade, if the Assign-WorkBasket pyWorkBasketAssignmentsDefinition report definition included the WHERE criteria .pxSystemFlow== 'FALSE', workbasket assignments for existing cases were not displayed in the harness. This was due to the new PXSYSTEMFLOW column in the pc_assign_workbasket DB table not properly handling this criteria, and a check has been added to resolve this.

SR-132569 · Issue 201349

Corrected portal refresh after chart unload

Resolved in Pega Version 7.1.8

When a chart is unloaded, a separate request was sent to the server to remove all chart-bounded data pages, i.e. pzRuntimeChartCleanup. If nothing is returned, the ActivityStatusSuccess Message was seen instead of the Work Item when the portal was refreshed. The API has been updated to return the correct information.

SR-129239 · Issue 200337

Added handling for Flow not at Task error

Resolved in Pega Version 7.1.8

Flow not at task and flow removed errors were appearing sporadically. This happened when the trigger fired off the commit inside the post-processing called CorrUpdateNoWO and returned a stale copy of the Workobject, and was complicated by an assumption that was trying to iterate over "pzInternalCaseFlow". This has been addressed in the CORRUPDATENOWO activity.

SR-131217 · Issue 199744

Stopped unexpected trigger caused by attaching note with gadget

Resolved in Pega Version 7.1.8

Declarative rules were being fired every time a note was attached to a work object using the "Notes" gadget (not advanced notes link). To fix this, the pxAttachNote activity has been updated to not trigger the declarative chaining in this scenario.

INC-161463 · Issue 638003

Case Dependency corrected for different access groups

Resolved in Pega Version 8.7

Creating a queue item as part of the case dependency was not working as expected when the access groups of the dependent cases were different. Investigation showed that in this scenario, the logic was looping differently and the DependencyList page in pxCheckFlowDependencies was getting removed. To resolve this, the DependencyList page has been moved so it is processed inside the DependencyList.pxResults loop.

INC-161948 · Issue 638963

Locking settings enabled for circumstanced case types

Resolved in Pega Version 8.7

Optimistic locking options were not present for a circumstanced case type, and the option to select the "Lock parent case when an action is performed on this case" check box was not available. However, when the parent case type was enabled with optimistic locking, a circumstanced child case could inherit a lock from its parent. Because "Lock parent case when an action is performed on this case" was not enabled on the circumstanced child case type, trying to update the parent case from the child case and save the parent case resulted in a "Lock not held on parent" error. This was a missed use case, and has been resolved by enabling locking settings in Case Designer for circumstanced case types.

INC-162168 · Issue 644731

Refresh works for nested lists

Resolved in Pega Version 8.7

After creating Pagelist A with another Pagelist within (B), a section was created with a repeating dynamic layout to display Pagelist A and a button was added with action set to refresh this section. In the embedded section of the repeating dynamic layout, a nested repeating dynamic layout was created for Pagelist B and a button was set to refresh this section. When using this configuration, the refresh was returning the actionID for Pagelist A regardless of which button was used. To resolve this, an update has been made which will iterate over the stack and append the individual indexes to the encoded value in the pzAPICreateJsonForField function.

INC-162763 · Issue 646109

Case creation and Save As performance improvements

Resolved in Pega Version 8.7

Performance improvements have been made to the getApplicationRuleSetList() function to avoid unnecessary and repetitive database calls.

INC-163154 · Issue 638100

Code updated for bulk actions buttons

Resolved in Pega Version 8.7

After upgrade, hovering over the "Filter case" button in pzBullkUpdate and the "Create" and "Clear" buttons in pzBulkAddActions caused them to disappear. The warning "This button generates markup that was used to support the older browsers. It is recommended that you update it to the newer markup" was shown, and an update code button appeared. Some custom rules exhibited the same behavior initially, but worked as expected after updating the code and saving them. This has been resolved by updating the buttons in pzBulkUpdate and pzAddBulkActions with the latest UI technologies used for button control codes.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us