SR-B12474 · Issue 282553

BIX extraction config documentation updated

Resolved in Pega Version 7.3

When using command-line BIX 7.1 to extract records and write them to a secondary database, it appeared that some of the records got skipped. This was actually expected behavior: as the records got updated while the extract was running, those particular updated records got skipped as they did not fall into the time range that user was passing. To eliminate this confusion, the log message has been clarified. In addition, the information in the Guide indicated that if bix/useHistoryClasses was set to true, the generated query should always use the history table and not the actual work object table. However, it was not made clear that the BIX code does not use this option for explicit command line arguments. Therefore, the following text has been added to the BIX documentation under "Configuring the extraction environment" -> "Configuring optional prconfig.xml settings": Including class instances added during a batch run To ensure that class instances added to the Pega Platform database after a batch run begins execution are included in the extract, add the following property:

SR-B12714 · Issue 294429

String comparison logic updated for complex property references

Resolved in Pega Version 7.3

Running a report that has a single page property (.Address.pyCountry) generated an error and the report shows no results. It worked correctly if the column is removed or a filter was added on instances that have .Address.pyCountry not null. This was an issue related to string comparisons, and has been resolved by updating the logic for parsing of complex references in UDFs.

SR-B12783 · Issue 285395

Performance improvements for Data Designer Visualizer

Resolved in Pega Version 7.3

In order to improve performance of the Visualizer feature of the data designer, the loading behavior has been changed. Previously, the RD being executed for each node in the graph to get the reference properties was defer loaded; this potentially caused issues if the data was still being loaded in the background for the visualizer and an attempt was made to open BodySite. To fix this issue, the defer loading has been removed and the data will load on click of the "visualizer" button.

SR-B12857 · Issue 285462

Repaired REST Connections with proxy

Resolved in Pega Version 7.3

After upgrade, connections to external internet websites/services were failing when using a proxy. This has been fixed.

SR-B13016 · Issue 284134

Report title shows for exported Excel; display report label name reverted

Resolved in Pega Version 7.3

Exported Excel reports were not showing the report title if the "display report filters" checkbox was unchecked in the RD rule. If the box was checked, the report title turned up in the Excel sheet, but the report UI showed an unnecessary blue bar if none of the filter criteria were set to be displayed as per business needs. The missing report title was traced to an error in the "display report filters" checkbox, and has been fixed. Additionally, the 'display report header' label in the pzReportViewerUserActions section had been recently modified to read 'display report filters', which was misleading - that change has been reverted.

SR-B13040 · Issue 293380

Improved reliability for GetReference API

Resolved in Pega Version 7.3

A sporadic issue with the OOB getReference API caused a failure in obtaining the absolute reference for a parameterized data page. This was caused by a race condition in the page handler, and synchronization has been improved to ensure the proper name will be set into the data page.

SR-B13040 · Issue 293526

Null DPI check added for async page load

Resolved in Pega Version 7.3

A null pointer exception was being generated when a data page was being loaded from the asynchronous cache and some exception occurred while switching the access group or getting a definition. To avoid this, a check has been added for a null DPI.

SR-B13606 · Issue 287616

Angle brackets escaped for RD drill down

Resolved in Pega Version 7.3

In a report definition with drill down, if the column parameter had a value that used the wrong parameter was getting passed in Query. This was due to the characters getting converted into their HTML equivalent < and >., and the character escaping has been corrected to resolve this.

SR-B13775 · Issue 293697

Resolved error in adding Association's Page Property in report browser

Resolved in Pega Version 7.3

Adding an Association's Page Property while creating a report in the Report browser generated an error on the screen. This was caused by incorrect passing of the class, and has been corrected.

SR-B13775 · Issue 286916

Resolved error in adding Association's Page Property in report browser

Resolved in Pega Version 7.3

Adding an Association's Page Property while creating a report in the Report browser generated an error on the screen. This was caused by incorrect passing of the class, and has been corrected.