SR-114438 · Issue 168461
Inbound mail processing for work creation refactored for subject line checking
Resolved in Pega Version 7.1.7
Some issues were found with the handling of inbound emails for work object creation. The activity CreateAndManageWorkFromEmail was incorrectly checking for an email subject line pre-condition and creating a new work object if the condition was not met. The CreateAndManageWorkFromEmail function has been refactored to correct this.
SR-114575 · Issue 168078
Search criteria passed to Report Definition
Resolved in Pega Version 7.1.7
The values entered in search criteria fields were not being passed to report definition, so the results were not shown in the Grid layout report. This was caused by an additional check on the classname of the parameters page while resolving filter values which are parameters, and has been resolved.
SR-114670 · Issue 166258
JMS MDB listener updated to support JMS 1.1
Resolved in Pega Version 7.1.7
A compatibility issue with SonicMQ generated the error "Caused by: javax.jms.JMSException: [JMSPool:169823]Failure occurred on createQueueConnection" during initialization of the response connection. To remedy this, PRPC has been updated to support JMS 1.1.
SR-114670 · Issue 169790
JMS MDB listener updated to support JMS 1.1
Resolved in Pega Version 7.1.7
A compatibility issue with SonicMQ generated the error "Caused by: javax.jms.JMSException: [JMSPool:169823]Failure occurred on createQueueConnection" during initialization of the response connection. To remedy this, PRPC has been updated to support JMS 1.1.
SR-114917 · Issue 166117
Alignment issues with IAC resolved
Resolved in Pega Version 7.1.7
When a dynamic layout of stacked style was used in conjunction with IAC, resizing the window caused the elements to not be properly aligned. CSS issues in the HTML handling of overflow properties have been corrected with the resizing harnesses.
SR-118050 · Issue 169612
Alignment issues with IAC resolved
Resolved in Pega Version 7.1.7
When a dynamic layout of stacked style was used in conjunction with IAC, resizing the window caused the elements to not be properly aligned. CSS issues in the HTML handling of overflow properties have been corrected with the resizing harnesses.
SR-115104 · Issue 165556
IAC functionality enhanced for secure environments
Resolved in Pega Version 7.1.7
In order to ensure IAC functionality in a secure environment, the following updates were made: HTTPOnly support has been enabled for prGatewaySESSIONID cookies; encryption and obfuscation have been set up for web nodes; added a check for login-config.xml to add default-users.properties and default-roles.properties to the other application-policy.
SR-115133 · Issue 166141
Localization added for column section summaries in Report Definition
Resolved in Pega Version 7.1.7
The summarize column section displayed while running the Report Definition now accepts localization.
SR-115308 · Issue 173906
Japanese character support added to Report Definition PDFs
Resolved in Pega Version 7.1.7
When Report Definition contains Japanese characters in its report name, column, value, etc., the exported PDF was not showing the Japanese characters incorrectly. This was due to a missing font-family for the PDF export mode, and has been corrected.
SR-115378 · Issue 168818
Corrected horizontal scroll bars for listviews with custom searches
Resolved in Pega Version 7.1.7
Horizontal scroll bars were not appearing when using custom search section in a list view. This error was caused by missing logic for resizing the window width, and has been corrected.