Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-D70674 · Issue 535483

Handling added for mobile upload of filename containing dots

Resolved in Pega Version 8.2.6

An issue with uploading a file name containing dots (such as 2019.12.12) while using the mobile browser has been resolved by updating the AttachFile activity in the propertyExist function.

SR-D73237 · Issue 539125

Pagination updated to resolve repeating Pulse notes

Resolved in Pega Version 8.2.6

After adding a case and entering 15 Pulse notes, scrolling down resulted in the notes being duplicated. Investigation traced this to entering more than 10 posts in a single interaction on a previously empty case when "Progressive pagination" was enabled for the repeating dynamic layout. On Private Edit, if the pagination was changed to "NONE" then the issue was resolved. Pagination depends on the pzPagingStartDateTime property, which is set on D_pzFeedParams, but since there were no results in this scenario this property was not being set. To resolve this, an update has been made so that pzPagingStartDateTime will be set if it is empty.

SR-D74246 · Issue 543725

Accessibility improved for Pega Survey Question pages

Resolved in Pega Version 8.2.6

Question Pages in Pega Survey lacked accessibility. This was traced to aria-label not being generated for Radio buttons and Drop-downs, and "title" not being generated for other controls used in Question and Question Pages. This has been resolved.

SR-D76927 · Issue 541422

VirusCheck added to all Pulse uploads

Resolved in Pega Version 8.2.6

The upload file activity has been updated to invoke VirusCheckActivity for all Pulse uploads.

SR-D50787 · Issue 520484

Excel time values will default to server datetime if operator time zone is null

Resolved in Pega Version 8.2.6

After upgrade, a scheduled report that contained a column using pxDateTime that was supposed to use EST instead used GMT when run and exported to Excel. This has been resolved with an update that will default to using the time zone of the server If the time zone of the operator is empty or null.

SR-D50819 · Issue 519237

Eligibility Builder integer sorting revised

Resolved in Pega Version 8.2.6

In 'Offer' on the Eligibility tab, the Builder was sorting integer properties by the value of the integer as a text string rather than the whole number. Example: 1, 10, 12, 13, 100, 2, 20, 29, 299, 3 instead of the expected 1, 2, 3, 10, 11, 12, 20, etc. This was traced to the system sorting the results using tools.sortPageList() in order to sort by localized (string) value, which is not appropriate for values of any type other than string. To resolve this, the system will skip the manual sort step for numeric columns since the values are appropriately sorted by the database.

SR-D53176 · Issue 541794

Error when adding function filter will persist

Resolved in Pega Version 8.2.6

When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.

SR-D55801 · Issue 524292

Corrected HTML error generated on export to PDF

Resolved in Pega Version 8.2.6

After exporting a report to PDF, the PDF could be viewed but repeated instances of the error "<th> missing ‘>’ for end of tag" were logged. This was traced to missing the closing '>' for th in the pzRRDataListHeaderRow HTML rule when "Enable column command menu" is unchecked in ReportViewer options, and has been corrected.

SR-D65256 · Issue 528006

DisplayCommandMenu holds value during runtime filter changes

Resolved in Pega Version 8.2.6

In report definition, under report viewer tab, the 'enable column command menu' option was disabled. When the report was launched, the menu was not displayed for each column as expected; after applying the filter changes, the column menu options were unexpectedly displayed. This was traced to previous work done on the implementation of the navigation menu for auto-generated grids. Because pyDisplayCommandMenu is exposed on the ruleform itself, disabling the command menu from the ruleform caused changes to the filter to reset and pyDisplayCommandMenu was set back to true regardless of what was configured on the ruleform. To correct this, updates have been made to ensure that pyDisplayCommandMenu is not overwritten when there are changes to a filter during runtime.

SR-D65327 · Issue 534570

Backspace keydown handler updated for all textinput modes

Resolved in Pega Version 8.2.6

Attempting to use the Backspace key to remove input from a number cell (either Integer or Decimal) did not work. When the action was performed by a Manager, the Backspace key works as expected. Investigation showed the logic in the keydown handler for the backspace key in pega_report_events.js was only ignoring the e.preventDefault() call when the textinput node type was text, not number or other input types. To correct this, the keydown handler has been updated so the backspace key in pega_report_events.js maintains the default backspace functionality for all textinput modes, not just those of type 'text'.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us