INC-119669 · Issue 562588

Special character handling added to filters for table sourced with parameterized RD

Resolved in Pega Version 8.1.9

Filters were not working on a table when sourced with a report definition which accepted a parameter value containing special characters (Eg: S&P). This has been resolved by using StringUtils.reversibleCrossScriptingFilter in the pzGetGridColUniqueValues activity to allow filters to contain special characters.

INC-145810 · Issue 599463

BIX log shows correct corrupted BLOB pzInskey

Resolved in Pega Version 8.1.9

An update has ben made to ensure the correct inskey is shown in the BIX logs for a corrupted BLOB.

SR-D90400 · Issue 563187

Explicit parent added for descendants in subreport to correct summary

Resolved in Pega Version 8.1.9

When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.

SR-D71408 · Issue 534932

DIrty check flag triggered by adding columns and filters

Resolved in Pega Version 8.1.8

If a report was edited and closed without saving, the dirty check worked as expected. However, if new columns or filters were added and the report closed without saving, the dirty check did not appear. This has been resolved by updating the check logic.

SR-D53176 · Issue 541793

Error when adding function filter will persist

Resolved in Pega Version 8.1.8

When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.

SR-D76204 · Issue 543591

Index conflict resolution logic updated

Resolved in Pega Version 8.1.8

After configuring a dedicated index on delivered Class - PegaCA-Interface-Contact, trying to generate the index resulted in an error indicating a type conflict in delivered classes/properties. This has been resolved by updating the conflict resolution logic.

SR-D50787 · Issue 520484

Excel time values will default to server datetime if operator time zone is null

Resolved in Pega Version 8.2.6

After upgrade, a scheduled report that contained a column using pxDateTime that was supposed to use EST instead used GMT when run and exported to Excel. This has been resolved with an update that will default to using the time zone of the server If the time zone of the operator is empty or null.

SR-D50819 · Issue 519237

Eligibility Builder integer sorting revised

Resolved in Pega Version 8.2.6

In 'Offer' on the Eligibility tab, the Builder was sorting integer properties by the value of the integer as a text string rather than the whole number. Example: 1, 10, 12, 13, 100, 2, 20, 29, 299, 3 instead of the expected 1, 2, 3, 10, 11, 12, 20, etc. This was traced to the system sorting the results using tools.sortPageList() in order to sort by localized (string) value, which is not appropriate for values of any type other than string. To resolve this, the system will skip the manual sort step for numeric columns since the values are appropriately sorted by the database.

SR-D53176 · Issue 541794

Error when adding function filter will persist

Resolved in Pega Version 8.2.6

When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.

SR-D55801 · Issue 524292

Corrected HTML error generated on export to PDF

Resolved in Pega Version 8.2.6

After exporting a report to PDF, the PDF could be viewed but repeated instances of the error "<th> missing ‘>’ for end of tag" were logged. This was traced to missing the closing '>' for th in the pzRRDataListHeaderRow HTML rule when "Enable column command menu" is unchecked in ReportViewer options, and has been corrected.