INC-119669 · Issue 562588
Special character handling added to filters for table sourced with parameterized RD
Resolved in Pega Version 8.1.9
Filters were not working on a table when sourced with a report definition which accepted a parameter value containing special characters (Eg: S&P). This has been resolved by using StringUtils.reversibleCrossScriptingFilter in the pzGetGridColUniqueValues activity to allow filters to contain special characters.
INC-145810 · Issue 599463
BIX log shows correct corrupted BLOB pzInskey
Resolved in Pega Version 8.1.9
An update has ben made to ensure the correct inskey is shown in the BIX logs for a corrupted BLOB.
SR-D90400 · Issue 563187
Explicit parent added for descendants in subreport to correct summary
Resolved in Pega Version 8.1.9
When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.
SR-D71408 · Issue 534932
DIrty check flag triggered by adding columns and filters
Resolved in Pega Version 8.1.8
If a report was edited and closed without saving, the dirty check worked as expected. However, if new columns or filters were added and the report closed without saving, the dirty check did not appear. This has been resolved by updating the check logic.
SR-D53176 · Issue 541793
Error when adding function filter will persist
Resolved in Pega Version 8.1.8
When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.
SR-D76204 · Issue 543591
Index conflict resolution logic updated
Resolved in Pega Version 8.1.8
After configuring a dedicated index on delivered Class - PegaCA-Interface-Contact, trying to generate the index resulted in an error indicating a type conflict in delivered classes/properties. This has been resolved by updating the conflict resolution logic.
INC-137009 · Issue 581892
Ad hoc reports saved successfully in private categories
Resolved in Pega Version 8.5.1
After upgrade, an error was seen when attempting to save an ad hoc report in a private category. Saving in a public category worked as expected. This was traced to the Rule-Shortcut.Validate activity, which attempted to use the Rule-Shortcut's RuleSet to find the Rule-Category. To resolve the saving issue, the Rule-Shortcut.Validate activity has been updated to do an Obj-Open on the Category instead.
INC-136643 · Issue 583367
Orphaned CSS reference removed from DisplayReport harness
Resolved in Pega Version 8.5.1
An intermittent invalid CSS error was appearing in the DisplayReport harness when an operation resulted in the regeneration of the harness content. This was traced to a reference to the workform_pyReportingSkin CSS, which was used in old reporting features and is not in use anymore. The reference has been removed to resolve this issue.
INC-131942 · Issue 574321
Orphaned CSS reference removed from DisplayReport harness
Resolved in Pega Version 8.5.1
An intermittent invalid CSS error was appearing in the DisplayReport harness when an operation resulted in the regeneration of the harness content. This was traced to a reference to the workform_pyReportingSkin CSS, which was used in old reporting features and is not in use anymore. The reference has been removed to resolve this issue.
INC-135719 · Issue 580691
Corrected reference exception for filter on a grid sourced from a parameterized report definition
Resolved in Pega Version 8.5.1
An Invalid Reference Exception was thrown after attempting to apply a filter on a grid sourced from a parameterized report definition. This was traced to work done to allow cross-scripting filters to allow filters to contain special characters, and has been resolved.