INC-131942 · Issue 574322
Orphaned CSS reference removed from DisplayReport harness
Resolved in Pega Version 8.2.8
An intermittent invalid CSS error was appearing in the DisplayReport harness when an operation resulted in the regeneration of the harness content. This was traced to a reference to the workform_pyReportingSkin CSS, which was used in old reporting features and is not in use anymore. The reference has been removed to resolve this issue.
INC-135719 · Issue 580689
Corrected reference exception for filter on a grid sourced from a parameterized report definition
Resolved in Pega Version 8.2.8
An Invalid Reference Exception was thrown after attempting to apply a filter on a grid sourced from a parameterized report definition. This was traced to work done to allow cross-scripting filters to allow filters to contain special characters, and has been resolved.
INC-140110 · Issue 600399
Large filter values accepted in Report Definition edit
Resolved in Pega Version 8.2.8
Report definition edit filter values were not accepting large comma separated values properly. This has been resolved by modifying the logic in RRFilters_Logic to use ReportFilter.getReportFilters.
INC-143191 · Issue 596470
Scheduled tasks landing page shows all tasks
Resolved in Pega Version 8.2.8
Due to pzGetScheduledTasks listview having a hardcoded limitation of 500 records to be fetched, not all scheduled tasks were being shown in the scheduled tasks landing page. This has been resolved by modifying the pyCreateSummary activity to use a newly created Report Definition to fetch data instead of list view.
INC-144756 · Issue 602724
Security improved for searches
Resolved in Pega Version 8.2.8
Authentication requirements have been added to activities associated with searching.
INC-120343 · Issue 573075
Explicit parent added for descendants in subreport to correct summary
Resolved in Pega Version 8.2.8
When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.
SR-D90400 · Issue 563185
Explicit parent added for descendants in subreport to correct summary
Resolved in Pega Version 8.2.8
When using a Report Definition with a Summarize column and a subreport with join class, it was not considering implementation class work objects. As a result, the prepared values were only partially computed. This was traced to the SubReport in SetQuery not having reference to a parent for the descendants classes, and has been resolved by explicitly setting the parent value.
INC-151293 · Issue 630347
Out of memory condition resolved for BIX extraction
Resolved in Pega Version 8.6.1
A node was going down automatically during execution of a BIX Extract rule when working with old objects. Investigation showed this was related to an out of memory error: the work object had nested page lists, and when one of the page lists contained a propertylist which contained more records, the system was trying to add entries to the LinkedList if any properties were missing the reference during extraction. Because LinkedList allowed duplicates, it filled with enough errors to cause the out of memory condition. To resolve this, LinkedList has been replaced with LinkedHasSet, which does not allow duplicates.
INC-160190 · Issue 658126
Logic updated to allow page property and declare index with the same name
Resolved in Pega Version 8.6.1
A Property which was in a page list which in turn was embedded in a Page was not visible in the Report Browser. This was traced to the two properties sharing the same name, and was caused by a check which ensured only entries with unique names were added. In order to support this configuration, logic has been added to pzAddPropListForClass_TreeGrid such that if a page property and declare index share the same name, they are both added to the tree grid.
INC-160608 · Issue 648636
Added handling for missing deleted/report shortcut for drilldown
Resolved in Pega Version 8.6.1
Whenever “Report Details” for a drilldown report without category was clicked, a Flow Action Error was generated. This was due to a missing Report shortcut normally stored in the Report Definition, and has been resolved by modifying pzPreProcessReportDetails to handle the edge case of a shortcut not present/deleted for a drill-down report.