INC-128880 · Issue 592817
Handling added for angle brackets in legacy Chart control
Resolved in Pega Version 8.3.5
When using Investigative Case Management, some report charts were not rendering correctly. This has been resolved by updating appendFormattedString in AbstractJsonDataGenerator.java to escape angled brackets (< and >) before appending the input.
INC-141322 · Issue 594513
Resolved drill up doubling the filter box
Resolved in Pega Version 8.3.5
When opening a report with a visual graph, clicking on one of the filtered options, leaving this box open (not submitting it) and then clicking on a bar in the visual graph of the report showed the contents of the graph, but then clicking on the report link to go back to the report overview caused a doubled filter box to be displayed. The report would then have to be reopened before being able to continue. The problem was that the value of .pyUI.pyConfigSecToShow was still set to "filter" after the drill down. When the drill back up happened, the report was trying to show the filter configuration section from before but the context was no longer available and it failed. This has been resolved by adding a call to pzCancelFilterLogicChanges in pzDrillUpReport to set the filters to the previous values and reset the value of pyConfigSecToShow.
INC-137317 · Issue 585404
Security improved for searches
Resolved in Pega Version 8.3.5
Authentication requirements have been added to activities associated with searching.
INC-139700 · Issue 591563
Shortcut works for copying reports into private rulesets
Resolved in Pega Version 8.3.5
Copying out of the box shortcuts to other categories in the Report Browser was failing with the error ".pyShortcutName: The rule name pyTimePerStage is a reserved name (starts with px, py, or pz) and is not created in a Pega- ruleset." This was caused by the system trying to create a new rule with a py prefix in a non pega- ruleset, which was a missed use case in the refactoring work of report actions to use the Record API. This has been corrected by moving the report ID generation logic from the activity pzValidateSaveAsInput to a new Rule-Utility-Function in the ReportingUtils library called pzGenerateUniqueRecordName so that it can also be used by pzCopyShortcutPostActivity7 when the shortcut's ID is prefixed with px, py, or pz.
INC-140701 · Issue 602862
The Report Resource Limit is applied on Job Scheduler
Resolved in Pega Version 8.3.5
The Job Scheduler was ignoring the application-wide limit for maximum number of rows to retrieve that was set on the Report > Settings landing page. If the limit was set on the Data Access tab of the report, it was honored. If it was set on the Application settings rule Pega-RulesEngine.pyMaxRecords it was not honored. This behavior was due to pzUpdateSystemSettings being called by pxRetrieveReportData. In pzUpdateSystemSettings, .pyContent.pyMaxRecords was updated to match the value in px.Requestor.pyReportSettings.pyMaxRecords. In some cases, that was not available and the max amount of records was not limited in that case. This has been resolved by updating pzUpdateSystemSettings to pull pyMaxRecords using @getRuleSystemSetting().
INC-174116 · Issue 662039
Added reporting on descendant classes for framework
Resolved in Pega Version 8.6.3
Reporting on descendant classes was not working as expected. In a report definition with "Reporting on descendant classes enabled," the framework class and implementation class each refers to two different tables that use the same names but belong to two different schemas. Investigation showed the generated SQL query was not adding the necessary UNION clause, and the records from the descendant classes were missing when running the report on framework class. This was a missed use case and has been corrected.
INC-181684 · Issue 665483
Privileges adjusted for RetrieveReportData
Resolved in Pega Version 8.6.3
In recent versions of Pega, pxRetrieveReportData was secured with @baseclass AllFlows and OpenDeveloperForm privileges. However, this can interfere with setting up roles after update. To resolve this, the privilege restrictions have been removed from pxRetrieveReportData as it is already protected by ABAC/RBAC.
INC-182193 · Issue 674802
Drilldown report takes original report prompt parameters
Resolved in Pega Version 8.6.3
When a report had prompt filters configured and the summary report definition was executed by giving prompt filters, drilling down to one of the records in the summary report display and then looking at the reports displayed and summarized on a column showed a mismatched count. This was found to be a very specific edge case that involved calling the "Summarize" action from a report column within a drilldown report when using a custom filter section and "prompt for filter changes" on the main report. Filters from the custom filter section were being propagated to the drilldown report when summarizing, but the drilled-down-and-summarized report itself had not been refreshed on the client side to reflect this. To resolve this, the actions have been copied from pyDefaultCustomFilterApplyCancel and applied to the Summarize selection in pzGridMenuNavRule.
INC-182381 · Issue 664455
Updated dedicated index reindexing check
Resolved in Pega Version 8.6.3
Attempts to reindex were not successful after a dedicated index failed with the error "Not enough active shards for index work to meet write consistency of quorum". This has been resolved by updating the system to validate the cluster state for the dedicated index name instead of the work index name when performing a dedicated index Reindex.
INC-182534 · Issue 677143
Resolved Sub Report Filter Criteria error
Resolved in Pega Version 8.6.3
After upgrade from Pega 7 to Pega 8, Sub Report filter criteria were throwing a runtime error when pyPartyFullName from Index-WorkPartyUri was used as a filter condition. Under certain conditions, Sub Report and Main report use class joins with the Index-WorkPartyUri table to get the count of cases. In this case, the error was caused by the ValidateFilterValue edit rule passing the wrong class name for the sub report class join property. This has been resolved.