SR-D91038 · Issue 553164
Corrected report with combo chart in Case Manager portal
Resolved in Pega Version 8.2.7
After adding the required columns a report in the report viewer and then adding a combo chart and dropping the summarized column on the y-axes and group by column on X-axis, clicking on "done editing" generated the error "pyUI.pyChart: You must have at least two Aggregate Columns in the chart series .pyUI.pyChart.pyDataAxis(1).pyChartOutputType: A Combo chart requires at least 1 Chart Type be a Column". Investigation showed that the second DataAxis page was getting deleted in the pzCleanChartDataAxis activity, causing the validation to fail. This has been resolved by adding a 'when' rule to "pzChartIsSingleY" that checks for "SingleYAxisClustered" chart and refers the same in pzCleanChartDataAxis to skip the data axis deletion.
SR-D94002 · Issue 553766
Export to Excel cell style control added
Resolved in Pega Version 8.2.7
If a column was formatted with an auto generated numeric control, a new cell style was generated for every row during the export to Excel process. Since there is a limit on the amount of cell styles, once the number of rows in the file was greater than 64000 an error was generated. To resolve this, the system will disable the creation of a new cell style for every instance when an auto-generated numeric control is used.