SR-B15663 · Issue 289919
Trend chart drilldown made consistent with chart display
Resolved in Pega Version 7.3
Trend chart drilldown did not match chart display due to issues with time zone being converted on the chart display but not on the the drilldown. When drilling down into a datetime group, the value of that group was used to create a single filter that matched the group (e.g., "Day of [.DateTime] = 20170101"). This caused the filter to match that time based on the server's time zone settings, not the user's (e.g., if the server was using GMT, then days always began at midnight GMT, so a user could drill down into a single day and get results spanning two days). To correct this, FusionChartDataGeneration.normalizeDateCal no longer localizes for the user's time zone if the time unit is larger than an hour, e.g. day or month units won't be normalized.
SR-B1734 · Issue 272443
Added content to blank headers for screen readers
Resolved in Pega Version 7.3
The out-of-the-box report browser previously used a grid where two of the table headers were blank, causing screen readers to not read out these two cells. This has been resolved with the addition of a binary transparent image and an associated tooltip to provide content for screen readers to act upon.
SR-B1734 · Issue 272039
Added content to blank headers for screen readers
Resolved in Pega Version 7.3
The out-of-the-box report browser previously used a grid where two of the table headers were blank, causing screen readers to not read out these two cells. This has been resolved with the addition of a binary transparent image and an associated tooltip to provide content for screen readers to act upon.
SR-B30410 · Issue 294913
Report drilldown works with 'do not display group headings'
Resolved in Pega Version 7.3
When sub-report properties were used in the main reports column source, the report definition displayed the expected results when clicking on a configured drilldown report and chart but displayed no results when listview dataset was clicked. This was traced to having "Do not display group headings" enabled in combination with drilldowns, and has been resolved.
SR-B30713 · Issue 296998
New activity pyCustomValidator added to pzValidateCustomFilterSection
Resolved in Pega Version 7.3
When a report definition enables "Prompt for filter changes before displaying report", and the report specifies a custom filter section, the harness that displays the custom filter section (pzRRDisplayCustomFilterSection) is Final and was not available to validate the fields in the custom filter section. To enable this use, a new available activity "pyCustomValidator" has been added and can be called from pzValidateCustomFilterSection.
SR-B31873 · Issue 298086
Review/Perform harness modifications for scheduled report errors
Resolved in Pega Version 7.3
Scheduled reports would periodically go to Completed state and stop running prematurely. Deleting and then reopening a scheduled report (from recents) caused corruption of scheduled reports that are re-scheduled. This was traced to the Review/Perform harness going in to a corrupt state, and has been corrected by re-building the Review harness as well as some minor changes to the Perform harness to ensure the correct buttons are displayed when deleting a scheduled report and reopening it from the recents list.
SR-B32056 · Issue 299068
CustomFusionChart display fixed for mobile HC
Resolved in Pega Version 7.3
Charts were not loading a second time unless a refresh of that section was forced after switching from one tab to other from the navigation panel on left side. This was an issue with charts created using pzCustomFusionChart erroring out when loaded within a layout group that requires the user to swipe left/right to view them in the hybrid client, and has been fixed.
SR-B33991 · Issue 292845
Corrected ability to hide filters for Export to PDF
Resolved in Pega Version 7.3
The "Display report filters" check-box was not being honored on export to PDF, causing the filters to always be shown. This has been corrected with an added visibility condition to show or hide a filter section based on the value of .pyDisplayReportHeader, and a check has been added in "RRBodyDiv" HTML rule to show header only when pyDisplayReportHeader is true.
SR-B35821 · Issue 296032
Extra space removed from "Filters: " in RD
Resolved in Pega Version 7.3
When a Report with a large number of columns was generated using Report Definition with enable add filters checked in the report definition rule, an unnecessary space appeared between the "Filters:" label and the filters. This has been removed.
SR-B37775 · Issue 300342
Action item refresh properly triggers
Resolved in Pega Version 7.3
Refresh was not clearing the temporary filters applied on the report definition results if the refresh option was triggered by the actions button. This has been fixed by adding a new java step to pzRunWrapper activity to clear the previously applied filters.