INC-202480 · Issue 699082

Resolved report filter section freeze

Resolved in Pega Version 8.6.4

When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.

SR-A14619 · Issue 229625

Alignment resolved for repeating grid headers

Resolved in Pega Version 7.2.1

Headers were mis-aligned in the UI Gallery for a repeating grid when the freeze header option was chosen along with pagination and width of the content. This was an issue with the initScrollbars function, and has been corrected.