SR-D7323 · Issue 493176
Pin Case to Board updated to use unique IDs for different workpools
Resolved in Pega Version 8.3.1
When using the Pin Case to Board functionality, it was only possible to find and pin cases in the default/current work pool of the working access group and not any other cases in any other work pools which allowed access to open/search/process. This was due to pyLabel being used to compare if a value entered was valid, which was not a unique key. To resolve this, the pyValidatePinDetails activity in Pega-Ext-Mentions-Documents, Pega-Ext-Mentions-Cases, and Pega-Ext-Mentions-Groups classes have been updated to compare pzInsKey instead of pyLabel to check for validate pin.
SR-D18853 · Issue 488283
Visibility on client check removed to enable Pulse on click
Resolved in Pega Version 8.3.1
When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.
SR-D37757 · Issue 507966
Pulse delete icon repaired
Resolved in Pega Version 8.3.1
After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.
SR-D44012 · Issue 509880
Added more error handling in pzCreateThumbnail
Resolved in Pega Version 8.3.1
In activity pzCreateThumbnail, a null pointer error was generated at step 2. This was traced to the value of originalImage being null even though there was no error in the image file itself, and has been resolved by adding an error check .
SR-D23906 · Issue 501993
Case status correctly updated when using RDA
Resolved in Pega Version 8.3.1
When a Assignment was routed to a work queue, and Flow Action post processing was set to trigger an RDA Automation to update some case property, an error appeared saying there was no data available on the Page and the case status was not updated when it moved to the next stage. This was an issue with case status not being correctly updated when using robotic automation, and has been resolved.