SR-D23906 · Issue 501993
Case status correctly updated when using RDA
Resolved in Pega Version 8.3.1
When a Assignment was routed to a work queue, and Flow Action post processing was set to trigger an RDA Automation to update some case property, an error appeared saying there was no data available on the Page and the case status was not updated when it moved to the next stage. This was an issue with case status not being correctly updated when using robotic automation, and has been resolved.
SR-C98068 · Issue 483990
Installer files updated with class loader conflict resolution assistance
Resolved in Pega Version 8.1.7
When sending emails with attachments, errors were observed relating to a loader constraint violation indicating that when resolving interface method, the class loader of the current class and the class loader for the method's defining class had different Class objects for the type used in the signature. The resolution for this requires user configuration of the app server, and the following files for the install guide have been updated with the appropriate information:Deployment-guides-dita/install.ditamap Deployment-guides-dita/Content/Topics/app-server-config/creating-jdbc-driver-module-jboss-tsk.dita Deployment-guides-dita/Content/Topics/app-server-config/delegating-javax-activation-to-JRE-loader-tsk.dita