INC-155276 · Issue 622816

Null check added for step page

Resolved in Pega Version 8.3.6

After creating and adding new Access Roles and application 'Access When' to the privileges instead of Production level, during run time the error "runtime.IndeterminateConditionalException: Trying to evaluate Rule-Access-When conditions L:IsProdAccess when there is no page to evaluate them against" appeared for the specific privileges. This was traced to a missed use case where the system falls back to the step page if the page for evaluating the 'when' condition is null, which did not account for scenarios where the step page can be null. To resolve this, a null check has been added which will fetch the primary page if the step page for the access 'when' condition is null.

INC-156647 · Issue 626293

Improved disconnected requestor cleanup for FieldService

Resolved in Pega Version 8.3.6

A large number of requestors from FieldService with the status as 'Disconnected' were accumulating and causing performance issues. This was traced to the requestors not getting passivated due to users not logging out and new requestors being created for the same users next time, and was caused by the value of the DSS Initialization/PersistRequestor being set as "OnTimeout". When the DSS prconfig/timeout/browser/default is not configured, the default browser requestor timeout is 60 minutes. In this scenario, requestors were not passivating as the requestor passivation timeout was set to the refresh token lifetime for mobile users, which was very large and overwrote the DSS value. This has been resolved by removing the code which set the passivation timeout to the OAuth2 refresh token lifetime.

INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

INC-118838 · Issue 560691

OKTA receives parameters on logout

Resolved in Pega Version 8.2.7

When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the DB, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.

SR-D95148 · Issue 557483

Port validation updated for redirect URI

Resolved in Pega Version 8.2.7

When an offline app for windows client was generated, trying to login via SSO resulted in the error "invalid redirect_uri". This was traced to the system validating the whole loopback redirection URL, e.g. "http://127.0.0.1:1234/redirection", including the port number. To enhance flexibility, an update has been made so that the port number will not be validated, allowing the client to establish it based on availability at the moment of the request to the authorization service. NOTE: As a best practice, a loopback URL should not be configured as a redirect URI. If a loopback URL is configured, then at run time the port number will not be validated, and the client application can use any available port on the system including ports that may not be intended for use.

SR-D62754 · Issue 559848

PrepareResponse updated to explictly close Input Handler

Resolved in Pega Version 8.2.7

When using prpcServiceUtils to export a product in a Windows+Weblogic environment, attempting to export repeatedly using the same archiveName with the intention of overwriting the older product with the newer one in the ServiceExport directory failed with a FileNotFoundException. Investigation showed that the product file that was created by the pzExport REST call was not being released by the Weblogic File Handler process. Due to this, the next time the call was invoked the system tried to create the same file in the directory but failed due to the earlier File handle lock. To resolve this, the system has been updated to explicitly close the InputStream using try-with-resources.

SR-D78274 · Issue 544092

Handling added for dual privileges with MSSQL

Resolved in Pega Version 8.2.7

After setting up dual privileges, the Admin user was able to create a table but the base user received an "insufficient privileges" error. Investigation showed this was an issue when using MSSQL: the generated grant statements used the server login name as the user in the grant statement, instead of the database user. For all other databases, the username passed into the connection is the correct user to use for grants. Only MSSQL has a distinction between this connection user name (the login) and the database user, and since the login did not exist in the user table, the grant failed. To resolve this, when MSSQL is used, the system will fetch the underlying database user when determining the user for grant statement generation.

SR-D84190 · Issue 547173

Post-Import Migration Agent query optimized

Resolved in Pega Version 8.2.7

A Post-Import Migration agent belonging to the Pega-ImportExport Ruleset and set to run every 60 seconds by default triggered the SQL query "select ASTERISK from pegadata.pca_CWT_CXP_Work_Interaction" which ran for an excessive amount of time, caused a utilization spike, and then crashed the utility nodes. Investigation showed the excessive run time and load was caused by the query fetching a very large number of results. To better handle this scenario, the query usage has been updated.

SR-D84364 · Issue 551400

Check for circular references added to SearchInventoryImpl to prevent recursive call

Resolved in Pega Version 8.2.7

An out of memory error was traced to SearchInventoryImpl infinitely recursing over a clipboard property, where the child property referenced a parent property and resulted in an endless loop. This has been resolved with the addition of a depth check to ensure that the search does not recurse infinitely.