SR-D90579 · Issue 550769
Real Time data flow exception during shutdown corrected
Resolved in Pega Version 8.2.7
A Real Time DataFlow run was failing with a java.util.concurrent.RejectedExecutionException. This occurred when the node was shutting down while picking up a partition, and was due to the life cycle events not being able to update the partition status. To resolve this, a check has been added to prevent the exception form occurring by evaluating whether the Executor is shutdown while distributing messages.
SR-D96836 · Issue 555748
Refinements made to MarkerNode memory use
Resolved in Pega Version 8.2.7
Significant memory usage can be observed when data join in strategies are missing the join conditions. E.g., when the primary source in the strategy can have up to 300 or even more propositions, the join without the join condition would perform a cartesian product with possibly up to 400 or even more records returned. This may cause performance degradation. To guard against this, an update has been made that seeks to prevent repetitive markers being accumulated under a MarkerNode while trying not to rely on any implementation of equality and hashCode for individual marker implementations.
INC-118838 · Issue 560691
OKTA receives parameters on logout
Resolved in Pega Version 8.2.7
When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the DB, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.
SR-D95148 · Issue 557483
Port validation updated for redirect URI
Resolved in Pega Version 8.2.7
When an offline app for windows client was generated, trying to login via SSO resulted in the error "invalid redirect_uri". This was traced to the system validating the whole loopback redirection URL, e.g. "http://127.0.0.1:1234/redirection", including the port number. To enhance flexibility, an update has been made so that the port number will not be validated, allowing the client to establish it based on availability at the moment of the request to the authorization service. NOTE: As a best practice, a loopback URL should not be configured as a redirect URI. If a loopback URL is configured, then at run time the port number will not be validated, and the client application can use any available port on the system including ports that may not be intended for use.