Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-133183 · Issue 205535

Fixed flow line distortion in Process Modeler

Resolved in Pega Version 7.1.9

When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.

SR-133184 · Issue 203710

Fixed flow line distortion in Process Modeler

Resolved in Pega Version 7.1.9

When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.

SR-131072 · Issue 203709

Requestor token creation added for PRExternal authentication

Resolved in Pega Version 7.1.9

When using a PRExternal authentication scheme, the csrfsession requestor token was not created. This caused a heavy volume of INFO logging messages in production due to the null token. This authentication path has now been added and the token will be correctly created for use.

SR-131691 · Issue 202207

Improved performance for incorrect password handling

Resolved in Pega Version 7.1.9

When the operator entered the wrong password in the login screen, numerous "Stream Overwritten" alerts appeared the Alert log. There was no workflow problem involved, but the logging indicated that there was an additional unnecessary call being made to Stream Web-Login, and that unneeded call has been removed to improve system performance and remove the error being logged.

SR-A1705 · Issue 205449

Fixed scrumboard intermittent failure

Resolved in Pega Version 7.1.9

After upgrading, it was seen that the scrumboard would intermittently fail to load, partially displaying and then hanging if the columns did not fit within the window boundaries due to the number of elements. This was traced to an error in the functionality that resizes parts of the scrumboard, and has been fixed.

SR-A4995 · Issue 213355

Fixed flow line distortion in Process Modeler

Resolved in Pega Version 7.1.9

When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.

SR-A4056 · Issue 211550

Corrected validation error for Extract rule field length

Resolved in Pega Version 7.1.9

A validation error noting that the field length of the table was limited to 30 characters was occurring when trying to check in an Extract rule even if the field value had been shortened. While checking in the extract rule, a block of code in the Rule-Utility-Function validateTreeProperties was recomputing the pagelist's table name instead of using the one provided by the user. The Rule-Utility-Function validateTreeProperties function has been modified to fix the issue.

INC-174781 · Issue 655123

Kerberos authentication added for external Cassandra

Resolved in Pega Version 8.4.6

Support has been added for Kerberos authentication with Cassandra.

INC-175207 · Issue 664362

Added handling for DSM Services stuck in leaving status after database outage

Resolved in Pega Version 8.4.6

During a database outage, the heartbeat would fail and DSM services would eventually try to enter safe mode and stop. As the first step they would try to change the state to LEAVING, but because the database was down saving the LEAVING state failed and the exception was not handled correctly. This resulted in the rest of the stop operation logic not being executed and the service being stuck in LEAVING. To resolve this, an update has been made to ensure the service goes to LEAVING_FAILED if anything fails during the stop operation including when setting state to LEAVING_FAILED. The state LEAVING_FAILED will get flushed to the database eventually when it comes back up. This will allow the aggregation service to start from the LEAVING_FAILED state and recover by itself after a database outage.

INC-176757 · Issue 657786

Interaction History properly saved when running strategy on a different data flow

Resolved in Pega Version 8.4.6

Customized Interaction History properties that had been added to pyInteractionHistoryConfiguration and pyDefaultWorkingSet and saved into the PR_DATA_IH_FACT table were not being saved properly after upgrading from 7.3 to 8.3. This was a missed use case and has been resolved.