SR-131072 · Issue 203709

Requestor token creation added for PRExternal authentication

Resolved in Pega Version 7.1.9

When using a PRExternal authentication scheme, the csrfsession requestor token was not created. This caused a heavy volume of INFO logging messages in production due to the null token. This authentication path has now been added and the token will be correctly created for use.

SR-131691 · Issue 202207

Improved performance for incorrect password handling

Resolved in Pega Version 7.1.9

When the operator entered the wrong password in the login screen, numerous "Stream Overwritten" alerts appeared the Alert log. There was no workflow problem involved, but the logging indicated that there was an additional unnecessary call being made to Stream Web-Login, and that unneeded call has been removed to improve system performance and remove the error being logged.

SR-A4056 · Issue 211550

Corrected validation error for Extract rule field length

Resolved in Pega Version 7.1.9

A validation error noting that the field length of the table was limited to 30 characters was occurring when trying to check in an Extract rule even if the field value had been shortened. While checking in the extract rule, a block of code in the Rule-Utility-Function validateTreeProperties was recomputing the pagelist's table name instead of using the one provided by the user. The Rule-Utility-Function validateTreeProperties function has been modified to fix the issue.

INC-118838 · Issue 560691

OKTA receives parameters on logout

Resolved in Pega Version 8.2.7

When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the DB, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.

SR-D95148 · Issue 557483

Port validation updated for redirect URI

Resolved in Pega Version 8.2.7

When an offline app for windows client was generated, trying to login via SSO resulted in the error "invalid redirect_uri". This was traced to the system validating the whole loopback redirection URL, e.g. "http://127.0.0.1:1234/redirection", including the port number. To enhance flexibility, an update has been made so that the port number will not be validated, allowing the client to establish it based on availability at the moment of the request to the authorization service. NOTE: As a best practice, a loopback URL should not be configured as a redirect URI. If a loopback URL is configured, then at run time the port number will not be validated, and the client application can use any available port on the system including ports that may not be intended for use.

INC-214974 · Issue 721181

Documentation updated for accessing D_pyUserInfoClaims

Resolved in Pega Version 8.6.5

When logging in using Org Credentials, trying to get the user details from D_pyUserInfoClaims did not return any information. This was due to the D_pyUserInfoClaims datapage being available only after authentication, so the claims information was not available during operator provisioning. The documentation located at https://docs.pega.com/security/86/mapping-operator-information-openid-connect-sso-authentication-service has been updated to include the following note: "This page becomes available and can only be accessed post authentication."

INC-201713 · Issue 700221

Resolved SSO logout error

Resolved in Pega Version 8.6.5

After configuring prconfig/initialization/Urlencryption/default -> true and prconfig/initialization/SubmitObfuscatedURL/default -> required, logging in to any portal using SSO resulted in a 400 error when trying to log out. This has been resolved by adding a call to the encryption Rule-Utility-Function while calling logoff activity from 'pzSingleLogoutServiceRedirectV2'.

INC-202702 · Issue 713726

Ruleset creation process updated to maintain thread scope

Resolved in Pega Version 8.6.5

On creating a ruleset, the system generated the error "There has been an issue. Please consult your system administrator." If browser cookies and site settings were cleared and the browser was relaunched before logging in and creating a ruleset, the issue did not occur. Investigation showed that the Application page was at the Requestor scope for some of the threads due to handling in the ruleset creation process that removed the Application page and recreated it in the default scope of the thread with the latest state. To resolve this, the process for deleting the Application page and recreating it on the Requestor page has been removed.

INC-212265 · Issue 714015

at+jwt header type support added

Resolved in Pega Version 8.6.5

After upgrading from Pega 7 to Pega 8, using JWT validation in the REST service package with type "at+jwt" resulted in the JSON web token being rejected during signature verification with the error "header "typ" (type) "at+jwt" not allowed". Pega uses the third-party Nimbus jar to generate and verify JWT tokens, and this issue was traced to a difference in the versions of that jar: Pega 7.3 uses the nimbus-jose-jwt 5.1 version jar, while Pega 8.6+ uses the 8.20 jar version. Nimbus rejects at+jwt header types by default from the 8.0 jar version. To resolve this and improve backwards compatibility, at+jwt header type support has been added.

INC-216154 · Issue 718236

SMTPPort parameter will be passed to ForgotPasswordUtil

Resolved in Pega Version 8.6.5

When a user triggered the "Trouble Signing in" function, the SentEmailNotification activity connection was trying to use port 25 even if the SMTP Port was configured as 587 in the Email Account instance. This was due to the SMTP Port not being passed to the SentEmailNotification activity, causing a fallback to port 25 for non-SSL connections. In order to ensure SendEmailNotification uses a specified port if configured, pySMTPPort will be passed to ForgotPasswordUtil.java.