INC-166995 · Issue 642440
DeleteDocumentPg added to allow list
Resolved in Pega Version 8.7
During performance testing with CSRF settings enabled, a '403 Forbidden' error was seen in the network trace when FinishAssignment called pyActivity=pyDeleteDocument on close action. This has been resolved by adding pyDeleteDocumentPg to the list of allowed activities.
INC-118838 · Issue 560691
OKTA receives parameters on logout
Resolved in Pega Version 8.2.7
When using an OIDC logout endpoint with a parameter set as a data page value, the data page retrieved the ID Token from the DB, but when logout was clicked the datapage name was being displayed in the browser instead of the IDToken. To resolve this, code has been added to support sending ID token parameters for logoff endpoint for OKTA logoff using OpeniD connect.
SR-D95148 · Issue 557483
Port validation updated for redirect URI
Resolved in Pega Version 8.2.7
When an offline app for windows client was generated, trying to login via SSO resulted in the error "invalid redirect_uri". This was traced to the system validating the whole loopback redirection URL, e.g. "http://127.0.0.1:1234/redirection", including the port number. To enhance flexibility, an update has been made so that the port number will not be validated, allowing the client to establish it based on availability at the moment of the request to the authorization service. NOTE: As a best practice, a loopback URL should not be configured as a redirect URI. If a loopback URL is configured, then at run time the port number will not be validated, and the client application can use any available port on the system including ports that may not be intended for use.
INC-157095 · Issue 638808
Enhancement added for tenant-level authentication
Resolved in Pega Version 8.7
In a multi-tenant PDC with a few tenants that utilize their own custom SSO, a pre-authentication activity inside a tenant that should block community access was also affecting tenants that did not have that pre-auth activity set. This was a missed use case and has been resolved by adding a tenantId hash in SchemePRAuth.makeUniqueSchemeName() to create the authServiceName.
INC-162434 · Issue 640051
LookUpList correctly executes during SSO login with model operator
Resolved in Pega Version 8.7
After configuring SSO to create operators on fly using a model operator, a new user logging in for the very first time had their operator ID created using the model operator, but after upgrade new users logging in to the system received the error "Only authenticated client may start this activity: RULE-OBJ-ACTIVITY @BASECLASS LOOKUPLIST". This was due to the methods used for additional security on the activity @baseclass LookUpList which allows it to only be run by authenticated users, and has been resolved.
INC-163201 · Issue 646910
BrowserFingerprint updated
Resolved in Pega Version 8.7
Security improvements have been added to the browser fingerprint process.
INC-163914 · Issue 668846
Improved Agile Studio passivation recovery
Resolved in Pega Version 8.7
When an Agile Studio session was passivated, the error "SECU0008 : CSRF Detected and Blocked" was seen. Reactivating the session resulted in a blank page. This was traced to the clearing of requestor level registrations added for that particular thread, and has been resolved by adding a new flag to identify if a thread is passivated along with the necessary structure for the conditionalized clearing of requestor level registrations based on this flag.
INC-164336 · Issue 634151
URL validation updated to handle custom token endpoints
Resolved in Pega Version 8.7
While saving an authentication profile with OAuth details, validation was failing for a valid URL given in the access token endpoint and revoke token endpoint fields. This was traced to the use of the Apache URL validator, which considered some domains to be invalid. To resolve this, the urlvalidator constructor has been updated to include a custom RegexValidator for access token and refresh token URLs.
INC-168837 · Issue 646972
CSRF token updated for use with OKTA login
Resolved in Pega Version 8.7
An issue seen while connecting via OKTA has been resolved by updating the CSRF token validation for use with IDP initiated SSO login.
INC-169186 · Issue 655537
Disconnect button availability extended
Resolved in Pega Version 8.7
A case was not refreshing when the disconnect button was selected while using the standard section for authorization grant type authentication. This was traced to a query executed to find a div with attribute pzInsHandle, but that attribute was not applicable in the user portal. To support this use, the query has been extended to be applicable for user portal (attribute data-ui-meta) and Dev Studio landing page.