Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-161463 · Issue 638000

Case Dependency corrected for different access groups

Resolved in Pega Version 8.3.6

Creating a queue item as part of the case dependency was not working as expected when the access groups of the dependent cases were different. Investigation showed that in this scenario, the logic was looping differently and the DependencyList page in pxCheckFlowDependencies was getting removed. To resolve this, the DependencyList page has been moved so it is processed inside the DependencyList.pxResults loop.

INC-163154 · Issue 638097

Code updated for bulk actions buttons

Resolved in Pega Version 8.3.6

After upgrade, hovering over the "Filter case" button in pzBullkUpdate and the "Create" and "Clear" buttons in pzBulkAddActions caused them to disappear. The warning "This button generates markup that was used to support the older browsers. It is recommended that you update it to the newer markup" was shown, and an update code button appeared. Some custom rules exhibited the same behavior initially, but worked as expected after updating the code and saving them. This has been resolved by updating the buttons in pzBulkUpdate and pzAddBulkActions with the latest UI technologies used for button control codes.

INC-164413 · Issue 636125

Updated timestamp handling for duplicate key issue with PyCompleteAutomation

Resolved in Pega Version 8.3.6

Occasionally a robot failed to complete a case due to a duplicate key exception. This was an issue with the History record creation due to duplicate key erlated to the timestamp, and has been resolved by updating the timestamp handling so that the REST API will use 'getCurrentTimeStampUnique' and for other cases 'pxGetCurrentTimeStampThreadUnique' will be used.

INC-172485 · Issue 649053

Check added for WorkParty property to catch changes

Resolved in Pega Version 8.3.6

After configuring a send email shape to send email to work parties, proceeding through the flow without work parties and then triggering the send email shape and creating the Fix correspondence assignment worked as expected. If the work party details were later updated and the send email shape was triggered again for the Fix correspondence assignment, the error message "No role defined to work object" appeared. This was an issue with the handling of the email flow the second time through: PyCorrPage.pyCorrPartyRole did not have the work object party details which were added to the work object after the fix correspondence assignment was created, and SendSimpleEmail was not designed to handle the email that needs to be retried during the FixCorrespondence flow call. To resolve this, the system will check whether the pyWorkParty property exists prior to calling the PartyCorrPreferences HTML rule.

INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

INC-187350 · Issue 703199

UUID added to iOS direct photo upload to differentiate filename

Resolved in Pega Version 8.7.2

When "Content Storage" with the option "Store in repository" was enabled on the "Integration" tab in the Application definition, it was not possible to add more that two attachments to a case with an iPhone when directly capturing a photo through the camera app instead of uploading the photo as an attachment using the gallery. When using the default "Store in Pega database", the additional photos could be uploaded directly from an iOS camera without any errors. Investigation showed that when "Store in repository" was enabled, a file name conflict check was done in the repository. Because the iOS camera app saves/uploads every image as "image.jpg", this caused the error when checking for a filename conflict in the repository. This has been resolved by adding code to append a UUID to the attachname when the device is mobile and browser is Apple Safari.

INC-192673 · Issue 706242

Tab highlighting updated

Resolved in Pega Version 8.7.2

Not all elements were indicated with yellow highlighting when tabbing through the screen. This has been resolved.

INC-194180 · Issue 704637

GetChildcases handling updated for large numbers of cases

Resolved in Pega Version 8.7.2

When a very high number of child cases being processed contained a wait shape that was dependent on the movement of a parent case, some of the cases were moved to the next step of the flow automatically while others required a manual command to ResumeFlow. In extreme cases where many child cases were waiting, a node crash could occur. This was traced to the pzGetChildcases report having a maximum value of 500 lines, and has been resolved by increasing the maximum number of rows to retrieve to 9999 in the Data Access Tab of the pzGetChildCases report definition. In addition, the pxCheckFlowDependencies activity has been modified to perform with a higher number of cases, and DSS(MaxRecords) logic has been added to split the child cases into multiple queue items for each access group to decrease load on each thread process.

INC-207218 · Issue 706368

Check added to prevent duplicate approval by single agent

Resolved in Pega Version 8.7.2

When using a cascading Approvals process supported both by a web access button or by responding via email, a single agent could use both methods and advance a case an additional step as if they were the next approval level. This was due to the system only checking the pzInsKey when processing the approval while the assignment key will be the same for the cascading approvals assignments. This has been resolved by introducing a datetime check to validate if the email approval assignment creation datetime and the one in the database have same value; if yes the approval process will proceed and if not it will exit.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us