SR-A76776 · Issue 254774
Pega Pulse Link Description text box handled dynamically
Resolved in Pega Version 7.2.2
To correct an issue where the Pega Pulse Link Description text box was not visible due to screen size (i.e., the Pega Pulse fields were not getting wrapped on the screen, the container for the pzLinkDescription section has been changed to use dynamic layout so it correctly adjusts according to the width.
SR-A91228 · Issue 258648
ConsiderLockingMode passed to GetNextWork
Resolved in Pega Version 7.2.2
When calling the OpenAndLockWork activity in the MoveToWorkList activity, the ConsiderLockingMode parameter was not being passed. This parameter value is checked to determine whether it is optimistic locking or not. To enhance the system, the First step of Assign-WorkList now sets the parameter ConsiderLockingMode to true/false based on based on the GetNextWork_MoveAssignmentToWorklist system setting so that optimistic locking is considered.
SR-A91228 · Issue 264407
ConsiderLockingMode passed to GetNextWork
Resolved in Pega Version 7.2.2
When calling the OpenAndLockWork activity in the MoveToWorkList activity, the ConsiderLockingMode parameter was not being passed. This parameter value is checked to determine whether it is optimistic locking or not. To enhance the system, the First step of Assign-WorkList now sets the parameter ConsiderLockingMode to true/false based on based on the GetNextWork_MoveAssignmentToWorklist system setting so that optimistic locking is considered.
SR-A88385 · Issue 257722
Thumbnail images consistently displayed in overlay
Resolved in Pega Version 7.2.2
When thumbnails were configured with the control pzAttachmentThumbnail), the overlay showed the image differently based on the location of the thumbnail in the screen, for example one side displaying with a scroll bar while the other did not. The earlier design was purely based on non-autogenerated code using a PopOver API call, which couldn't honor the position of the overlay. To resolve this, the Attach Field configuration has been modified so that all the Thumbnail overlays are shown using Local Action and thumbnails will be shown using autogenerated pxIcon control.
SR-A89637 · Issue 259256
Search for Work gadget updated to accept "StartsWith"
Resolved in Pega Version 7.2.2
When using a fixed portal, the Search for Work gadget was not working for the option "Starts With" when pxOperatorMap rule was being called from newly added Property-Map-Value methods. This was caused by pxOperatorMap not having a return value for StartsWith, causing the default value"=" to be returned. This has been fixed by adding a return value for "StartsWith", "NotStartsWith", "EndsWith", "NotEndsWith", "Contains", "NotContain", "IsNull", and "IsNotNull" in pxOperatorMap.
SR-A90472 · Issue 258243
Population handling added for null value flowType property
Resolved in Pega Version 7.2.2
While launching the case local action, a clipboard error was generated indicating the InternalStageFlow failed to find the named RULE-OBJ-FLOW. This was caused by a null flowType property value in the PegaProComUtilities populateFlowActions--(ClipboardPage, ClipboardPage, PublicAPI) function due to the order of actions, and the system has been updated to seek the flowType property of an assignment if it encounters a null value.
SR-A91743 · Issue 259136
Security update for pxInitials control
Resolved in Pega Version 7.2.2
XSS (Cross Scripting Filter) has been added for potentially exploitable parameters in the pxInitials control.
SR-A87552 · Issue 257706
Implicit privileges do not generate warnings
Resolved in Pega Version 7.2.2
RARO with implicit privileges was generating warnings that affected the compliance score. There is a particular format for declaring implicit privileges. i.e. Classname:ruleName, and the system has been updated with a check for this so implicit privileges will not be adding any guardrail warnings.
SR-A101006 · Issue 272734
JDBC password handling corrected
Resolved in Pega Version 7.2.2
After upgrade, a JDBC database connection on WebSphere 8.5/Oracle 11G indicated success on test connection, but a username/password "connection could not be obtained" error was thrown when attempting to save the connection. This was due to the handling of the encrypted password, and has been fixed.
SR-A101808 · Issue 269472
WebSphere deployment documentation updated to clarify JVM configuration advice
Resolved in Pega Version 7.2.2
The deployment guides for WebSphere have been updated to clearly distinguish between Oracle and IBM JVM when providing JVM configuration advice.