INC-152442 · Issue 616668

Check added for Create Access to attachment

Resolved in Pega Version 8.4.4

After restricting access for the attachments category in a CS application, the attachment was added without category and could not be opened. This was due to the Create Attachment access not being automatically created for all categories when privileges were added, and has been resolved by adding a step to check Create Access for attachments of the respective category.

INC-153688 · Issue 616919

Class name length limitation raised to 64 characters

Resolved in Pega Version 8.4.4

In order to support field audits on very long class names, FLAudit Class has been modified to allow a class Name length of 64 characters instead of the previous limit of 56.

INC-154189 · Issue 617247

Harness used to determine read-only for button/text input

Resolved in Pega Version 8.4.4

If a button/text input was configured to always be editable in a section by using the /v1/cases/{ID}/pages/{pageID} API (say i.e PageID as Review), the button/text input was always returned as readonly. This was due to the API being hardcoded to return readonly info, and has been resolved by updating pzGetPageDetails to not force read-only and let the harness configuration decide the behavior.

INC-154826 · Issue 614818

Enhanced handling for screen/non-screen/screen flow movement

Resolved in Pega Version 8.4.4

When using a screen flow where the last screen had a link to launch a section, a cancel button in the section that was configured with a data transform and a 'Finish Assignment' intended to move back to the screen flow did not work as expected. If a browser refresh was performed and then the cancel button was clicked, the Finish Assignment / return was triggered as expected. Because this configuration navigated to a non-screen flow, the attachOnLoad function did not load the parameter needed for maintaining error messages. This has been resolved by updating the navigation to handle this use.

INC-155469 · Issue 616912

Attach Documents Control updated for busy indicator timing

Resolved in Pega Version 8.4.4

When using the standard control - Attach content - to attach documents for processing in the application, selecting multiple files for upload and then clicking on the attach button before the busy indicator started resulted in not all files being uploaded. Investigation showed that the busy indicator was not set to display as soon as the attachments were added, giving an opportunity to click "Attach" before all the documents could be successfully added to the process. As part of the resolution for this issue, the busy indicator will be displayed immediately upon file selection.

INC-140279 · Issue 597756

JMX logging added to upgrade diagnostics

Resolved in Pega Version 8.4.4

In order to improve diagnostic information, infoForced loggers have been added for debugging upgrade issues related to JMX calls to enable and disable rules creation.

INC-144555 · Issue 603071

Changelog cleanup added for de-optimized properties

Resolved in Pega Version 8.4.4

Unwanted optimization was automatically added to properties for the Application-Work-Casetype class created using the wizard in the App Studio. Attempts to remove the optimization did not work: the property advance tab was showing the optimized classes details even after deleting and recreating the property. When a property is optimized the system adds entries to pr_changelog for the list of classes it has optimized. When the property was deleted, the pr_changelog was not cleared. This was a missed usecase, and has been resolved by overriding the Cleanup activity at Rule-Obj-Property class to delete the pr_changelog entry associated with that if it is present.

INC-144869 · Issue 606617

Improved ScalarPropertiesWriter logging

Resolved in Pega Version 8.4.4

In order to improve diagnostics, debug loggers have been added to ScalarPropertiesWriter.java to print column name in the logs while creating map between column names and their values from clipboard page.

INC-146595 · Issue 604791

Initialized entryName for light weight inventory instance

Resolved in Pega Version 8.4.4

When running deployment on a new pipeline created for the next minor version, once the deployment process got to the point of showing aged updates, the “view aged updates” came back as blank screen. Viewing the logs showed the aged update elements come back but were missing the pyName associated with them. Investigation showed that the system did not have support for setting the mEntryName for LightweightInventoryInstance objects. This has been resolved by adding a junit to ensure that getEntryName() doesn't return as null and should be equal to pzInsKey.

INC-148154 · Issue 602922

Hot Fix Manager updated to use installation order for schema import

Resolved in Pega Version 8.4.4

Schema changes were not being imported during the hot fix manager DL import process. Investigation showed this was due to hotfixes in the DL being iterated over from newest to oldest, causing older hotfixes to replace the value added to a map by the newer. To resolve this, the system has been updated to use hotfix install order, which considers selected and dependent hotfixes, rather than ordering newest to oldest. This ensures that newer table representations will override older rather than the other way around.