SR-122314 · Issue 178491

Resolved installation errors for DB2 Z/OS with WebSphere

Resolved in Pega Version 7.1.8

A problem was encountered while installing split schema on a DB2 z/OS system with WebSphere. This was caused by an erroneous system setting where the ports to the DB2 database were not open in this environment. While the Admin could correct the environment to open the ports and allow the application server node to connect to the DB2 database, this has been changed in the software to default to the correct settings.

SR-122440 · Issue 183753

Corrected text wrap for cases

Resolved in Pega Version 7.1.8

Text wrapping was not happening automatically in long history descriptions in a case. This was due to a missing function and has been corrected.

SR-122493 · Issue 190767

Support added for conditional page list properties

Resolved in Pega Version 7.1.8

After upgrading, validate rules on aggregate properties had unexpected behaviors. This rule formation was inadvertently allowed in some earlier versions despite guardrails, so support for these conditional page list properties has been added in order to enhance backwards compatibility.

SR-122504 · Issue 189293

Made operator identification consistent across flows

Resolved in Pega Version 7.1.8

A naming difference was seen in work flows depending on whether Visio or modular functions were used: Visio picks the "Task_Assignment2" function to generate java for assignment, giving the operator ID, but modular flows use "Task_Assignment" and show the operator name. In order to show consistent behavior, the code has been modified such that it first gets the operator name from the assign page if it exists, and it does not exist it will fall back to sending the operator ID as parameter.

SR-122559 · Issue 181629

Removed pagination from GetBinaryFiles RD to ensure all records are reported

Resolved in Pega Version 7.1.8

When attaching content smart shapes in Standard flow, not all results were shown if pagination was enabled. This was caused by the pagination limiting the returned information to 50 records, and manifested as Binary File path autocomplete not showing all the results, the open rule icon not working even if the binary file rule existed, FileKey only being generated if the file was selected from the autocomplete list, and an Invalid file attachment error if an existing binary file was accessed. In order to resolve this work flow issue, pagination has been disabled in the GetBinaryFiles report definition.

SR-122559 · Issue 179977

Removed pagination from GetBinaryFiles RD to ensure all records are reported

Resolved in Pega Version 7.1.8

When attaching content smart shapes in Standard flow, not all results were shown if pagination was enabled. This was caused by the pagination limiting the returned information to 50 records, and manifested as Binary File path autocomplete not showing all the results, the open rule icon not working even if the binary file rule existed, FileKey only being generated if the file was selected from the autocomplete list, and an Invalid file attachment error if an existing binary file was accessed. In order to resolve this work flow issue, pagination has been disabled in the GetBinaryFiles report definition.

SR-122591 · Issue 183772

Addressed migrate.bat file datetime format issue

Resolved in Pega Version 7.1.8

The script 'migrate.bat' sets up a logfile name based on the current time/date. However, the script was only working when using United States/English as the locale where the format of the '%date%' variable was MM/DD/YYYY, and failed with an obscure error in locales using the DD/MM/YYYY format. There was a local change of hardcoding the 'TIMESTAMP' variable, but this has been resolved by adding the use of a local insensitive datetime from the WMIC utility on Windows systems for the install.bat, upgrade.bat, resume.bat and migrate.bat scripts. The WMIC utility (Windows Management Interface Cmdline) is supported in XP and beyond.

SR-122637 · Issue 183016

MaxFileLength property added to avoid truncating attachment names

Resolved in Pega Version 7.1.8

While adding the attachments to the case using drag and drop functionality, the file name and file description were being truncated. However, a new property named "pyMaxFileLength" is now available as an override in pyDefault Model to set a different name limit. If this property is not set, it will take the default value of 60 and proceed. Also for UI error messages, pyNote property in Data-WorkAttach-File and Embed-DragDropFile in the application ruleset must have the max length limitation removed from there or the MaxFileLength will be overridden by that setting.

SR-122757 · Issue 185151

Chinese filename issue with Microsoft Internet Explorer resolved

Resolved in Pega Version 7.1.8

When using the Chinese version of the Microsoft Internet Explorer browser and the out-of-the-box attachment gadget to attach files, dragging and dropping a file with Chinese characters in the file name caused the name to become corrupted. This issue was due to the encoding method, and has been resolved by removed the encoding for the filename.

SR-122761 · Issue 188488

Tuned logic for propagating shape flow actions

Resolved in Pega Version 7.1.8

When a work flow has moved from an assignment shape to an assignment service shape, the other actions menu was showing the flow action from the previous assignment. Work-.Connect activity invoked populateFlowActions function to populate the assignment local action. By the time this was invoked, the pxFlow() was not updated with the correct assignment details and the old assignments actions were being populated. This has been fixed by tuning the logic of invoking populateFlowActions.