INC-130304 · Issue 567925
Retry logic added for downloading upgraded rules
Resolved in Pega Version 8.2.8
A Rules upgrade failed while downloading applications from the maintenance server due to an SFTP server connection failure. This has been resolved by adding logic to retry if the first connection attempt fails.
INC-132218 · Issue 573358
Resolved buffer overflow for Migration loadDatabase
Resolved in Pega Version 8.2.8
A Rules upgrade failed in the Migration step at loadDatabase stage, involving the move of all the table records from old schema to new schema. This was traced to the inability of Migration to load blob of sizes more than 100 MB, and has been resolved by updating Migration to use byte[] to read the blob content with the help of metadata that contains blob length.
INC-133202 · Issue 574700
TableRenameUtil hashing improved
Resolved in Pega Version 8.2.8
During index name generation, the algorithm that was responsible for index name uniqueness was sometimes insufficient and cerated a loop condition. This has been resolved by using a stronger hash algorithm and refactoring the code that could result in a loop.
INC-177323 · Issue 672422
Search string wildcard use documentation updated
Resolved in Pega Version 8.6.3
The support article for the search API has been updated to clarify the ability to use the wildcard character "*" by manually adding it to the prefix of each term in the search string.
INC-190130 · Issue 678542
Help information updated for using Elastic Search with Report Definition
Resolved in Pega Version 8.6.3
The support article "Configuring a report definition to run against an Elasticsearch index" has been updated to clarify that the search can pass multiple values with a space in pySearchString as it does OR operation on all the fields, and that filters in the report definition will be used when executing the report directly or when calling the report in the pxRetrieveSearchData activity.
INC-145293 · Issue 610933
Additional diagnostic logging added for ElasticSearch startup issues
Resolved in Pega Version 8.6.3
The PyIndexerState was stuck in Starting status during node initialization. This issue could occur if the filesystem became hung due to network level issue while scanning entries from /etc/mtab, resulting in a lock which was not released correctly. In order to better determine which node entry in a cluster may be responsible for the hang, an update has been made which will use a temporary virtual environment to repeat the part of the initialization phase responsible and generate additional logs for debugging. To activate this, the PegaSearch.Diagnostics logger must be set in DEBUG mode. This duplicated virtual initialization will not interrupt the normal initialization.
INC-153849 · Issue 641923
Updated replica management for search clusters
Resolved in Pega Version 8.6.3
When using a cluster with two Universal nodes in the cluster, a daily restart process where the second node was not started until the first was fully up resulted in Search initialization failing for the first node while becoming active on the second node. This was traced to the methods used in increasing and decreasing replicas. This has been resolved by revising the handling of ElasticSearch node lifecycle and replicas through a new option "Dindex.searchNodeCount " which includes a specification for the number of expected search nodes. If this option is not present, the old method will be used.
INC-168003 · Issue 655376
BIX Total Instance count matches manifest
Resolved in Pega Version 8.6.3
The BIX Manifest file was showing a count mismatch when the BIX Manifest and Extract files were shared with downstream teams, causing data to not be accepted by the downstream application. Investigation showed this occurred for an embedded page list property in the sequence that was missed and not considered. To resolve this, a DSS has been added: when BIX/generateAllEmptySubscriptForPageList is set to true, an empty subscript will be generated for the missed properties.
INC-178002 · Issue 663769
Restore point handling updated for absent pzpvstream column
Resolved in Pega Version 8.6.3
While executing the “get restore point” action for rollback, a PZPVSTREAMerror error occurred with the message "(util.HistoryCollectorDataModel) WARN|Rest|SystemManagement|v2|restorepoint - History collection for the table will be slow because it does not have all of the required columns". This was a missed use case for Robotics Automation not having a pzpvstream column for one of the tables; this has been corrected with a check to validate for pzpvstream column so the system will not seek history records if the pzpvstream column is not present.
INC-181941 · Issue 664807
Handling added for using virtual network interface for Stream Services startup
Resolved in Pega Version 8.6.3
After update, the restart of any node failed with the error "Unable to create DSM service DATA-DECISION-SERVICE-STREAMSERVER DEFAULT". This has been resolved by adding support for allowing stream service to start on the virtual network interface in cases where it was explicitly configured via the "cluster/hazelcast/interface".