INC-160382 · Issue 630714

Added handling for double quotes when converting tables

Resolved in Pega Version 8.6

After importing some packages from development to production, DDL conversion failed for tables with 30 characters in the table name when the import file contained a "Create VIEW" sentence. This was due to the addition of double quotes (" "). The table rename utility was not expecting to handle quoted table names, so as a result the addition of the quotation mark characters were included in the length calculation, and when renaming was performed it yielded syntactically invalid names (with leading " in the name). To resolve this, an update has been made which will strip quotes from table names being passed into TableRenameUtil.

INC-162360 · Issue 635817

Unneeded AUC error percentage calculation removed for better system performance

Resolved in Pega Version 8.6

When generating snapshots of the ADM models, an inefficiency in the metric calculation for the AUC error percentage caused an excessive amount of memory to be allocated which could cause slowdown or require a system reboot. This has been resolved by removing the problematic AUC error percentage calculation as it is not used in the UI.

INC-163940 · Issue 634491

CustomerData schema added to list of databases for optimization

Resolved in Pega Version 8.6

was no "Create?" column. This column appeared for the PegaDATA database but not for CustomerData. To resolve this, the Optimize Schema Landing Page has been updated to treat the CustomerData schema as a shipped Pega database.

INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

SR-C93602 · Issue 485517

White list filter added for X-Forward-Host value security

Resolved in Pega Version 8.3.2

In order to improve security, a validation for X-Forward-Host value has been added which will be read from a local configuration. This is in the form of a white list regex filter for the host/XFHost header to ensure the URL's actions cannot be redirected.

SR-D37894 · Issue 505974

Query parameters will be cleared after redirection from authentication

Resolved in Pega Version 8.3.2

When using the /PRAuth Servlet, running a snapstart URL generated from a secondary application correctly executed SAML Authentication and Pega processing, but a second URL generated with different parameters ran with the parameters from the first request. The third and subsequent requests processed as expected with the parameters sent in with the request. Investigation showed that the previous parameters were picked due to the query string parameters not being cleared after redirection, and this issue has been resolved by updating the system so it will clear the parameters after issuing a redirect from the authentication policy engine.

SR-D41454 · Issue 506535

Updated HotFix Manager for use in older versions

Resolved in Pega Version 8.3.2

The DL logic in Hotfix Manager was changed in 8.3 to include the catalog of all framework changes. This had the unintended side effect of preventing DLs from being installed in Pega 7.3.1 and lower versions as the versions included in the catalog are not present on those systems and the validation failed. This has been resolved by revising the DL update so the system will only add all apps to the catalog for platform 7.4+ DLs.

SR-D46133 · Issue 534649

Colon in folder or file name will be replaced with underscore during unzip

Resolved in Pega Version 8.3.2

After creating a product file (zip), attempting to import the same file into an updated system resulted in an exception. Investigation showed that in this case the zip file was a Product rule form which had applications packaged with a colon(:) in the name of the application, a format that was allowed in 6.x versions. Because Windows machines restrict creating creating any folder or file with : in its name, the zip file could not be inflated as part of the import process. To resolve this, the system has been updated so that a colon(:) will be replaced by underscore(_) during inflate operations.

SR-D46536 · Issue 515792

Custom agent next run time will be rescheduled if the run failed

Resolved in Pega Version 8.3.2

If a customized agent that was set to run every day encountered an exception and failed to run, restarting the agent did not update it to the next run time; it still returned the passed trigger time as its next execution time. This has been resolved with an update that will reschedule the run if the next run time is in the past.