INC-140279 · Issue 597756

JMX logging added to upgrade diagnostics

Resolved in Pega Version 8.4.4

In order to improve diagnostic information, infoForced loggers have been added for debugging upgrade issues related to JMX calls to enable and disable rules creation.

INC-144555 · Issue 603071

Changelog cleanup added for de-optimized properties

Resolved in Pega Version 8.4.4

Unwanted optimization was automatically added to properties for the Application-Work-Casetype class created using the wizard in the App Studio. Attempts to remove the optimization did not work: the property advance tab was showing the optimized classes details even after deleting and recreating the property. When a property is optimized the system adds entries to pr_changelog for the list of classes it has optimized. When the property was deleted, the pr_changelog was not cleared. This was a missed usecase, and has been resolved by overriding the Cleanup activity at Rule-Obj-Property class to delete the pr_changelog entry associated with that if it is present.

INC-144869 · Issue 606617

Improved ScalarPropertiesWriter logging

Resolved in Pega Version 8.4.4

In order to improve diagnostics, debug loggers have been added to ScalarPropertiesWriter.java to print column name in the logs while creating map between column names and their values from clipboard page.

INC-146595 · Issue 604791

Initialized entryName for light weight inventory instance

Resolved in Pega Version 8.4.4

When running deployment on a new pipeline created for the next minor version, once the deployment process got to the point of showing aged updates, the “view aged updates” came back as blank screen. Viewing the logs showed the aged update elements come back but were missing the pyName associated with them. Investigation showed that the system did not have support for setting the mEntryName for LightweightInventoryInstance objects. This has been resolved by adding a junit to ensure that getEntryName() doesn't return as null and should be equal to pzInsKey.

INC-148154 · Issue 602922

Hot Fix Manager updated to use installation order for schema import

Resolved in Pega Version 8.4.4

Schema changes were not being imported during the hot fix manager DL import process. Investigation showed this was due to hotfixes in the DL being iterated over from newest to oldest, causing older hotfixes to replace the value added to a map by the newer. To resolve this, the system has been updated to use hotfix install order, which considers selected and dependent hotfixes, rather than ordering newest to oldest. This ensures that newer table representations will override older rather than the other way around.

INC-215937 · Issue 713773

Added exception handling for PageGroup alerts

Resolved in Pega Version 8.6.5

Queue items were going to the broken queue if there was an issue fetching the alert configuration from the Queue Processor rule. The error "java.lang.IllegalArgumentException: Alert id cannot be blank" was seen. This has been resolved by adding exception handling while gathering alerts from PageGroup so that a malformed alert configuration will not cause overall failure of a processed message, but instead an empty alert will be returned if configuration-data is corrupted.

INC-217781 · Issue 714185

JobScheduler updated to better handle DST change

Resolved in Pega Version 8.6.5

If a job scheduler was set to run on a weekly basis between 1 AM CET and 3 AM CET, the DST time change caused the job scheduler to skip that week. During DST, there is one 23-hour day in the year, and if execution time is set to that missing hour the system was throwing an IllegalArgumentException for the non-existent date. This has been resolved by adding a check that verifies whether a given date does exist; if it does not exist, the system will postpone execution time by one hour.

INC-218001 · Issue 719922

Error text revised for parameterized data page used for token generation

Resolved in Pega Version 8.6.5

While trying to add a claim in the header of a Token Generation Profile instance, selecting Map From as "Clipboard" and trying to give any DataPage(parameterized) as the source property failed to be saved and the error "JWS Alias— Please provide correct algorithm key with correct key length." appeared. Changing the "Map From" to a Constant and giving a dummy value worked as expected. Tracer showed the error "declare page parameters not supported by PropertyReference", indicating the actual issue: at this time, the Token profile does not support using a parameterized data page. This has been addressed by ensuring an appropriate error message is shown on save of the token profile rule form when a parameterized data page reference is configured. The error will now read "The reference D_pzPreferenceStore[PreferenceOperatorID:"[email protected]"].pxObjClass is not valid. Reason: Parameterized data page reference is not supported." Support for a parameterized data page used with Map From will be taken as an enhancement for a future release.

INC-218340 · Issue 714663

Override added to delete records for a stream dataset after processing

Resolved in Pega Version 8.6.5

Kafka data was accumulating for a Stream data set due to huge volume of inbound calls. This has been resolved by adding support to override pyDeletedProcessed through a DASS in order to remove the records for a particular stream dataset (topic) as soon as they are processed by Pega.

INC-218909 · Issue 715282

Override added to delete records for a stream dataset after processing

Resolved in Pega Version 8.6.5

Kafka data was accumulating for a Stream data set due to huge volume of inbound calls. This has been resolved by adding support to override pyDeletedProcessed through a DASS in order to remove the records for a particular stream dataset (topic) as soon as they are processed by Pega.