INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

SR-C98068 · Issue 483991

Installer files updated with class loader conflict resolution assistance

Resolved in Pega Version 8.2.4

When sending emails with attachments, errors were observed relating to a loader constraint violation indicating that when resolving interface method, the class loader of the current class and the class loader for the method's defining class had different Class objects for the type used in the signature. The resolution for this requires user configuration of the app server, and the following files for the install guide have been updated with the appropriate information:Deployment-guides-dita/install.ditamap Deployment-guides-dita/Content/Topics/app-server-config/creating-jdbc-driver-module-jboss-tsk.dita Deployment-guides-dita/Content/Topics/app-server-config/delegating-javax-activation-to-JRE-loader-tsk.dita

SR-D28460 · Issue 509365

Added timeout handling for non-PRAuth servlets

Resolved in Pega Version 8.2.4

After logging in via external authentication service (SAML Single Sign On) and setting up a timeout in the access group RuleForm, when the user performed any action and the server identified the request to be timed-out, it was expected that a SAML request would be sent from the browser to the external Authentication Server (referred as IDP) and the flow would proceed from there. This worked as expected for a non-AJAX request. To resolve this, handling has been added for timeout when using non-PRAuth authentication services.

SR-D29127 · Issue 506863

SAML data pages restored after passivation

Resolved in Pega Version 8.2.4

If login used SAML SSO, resuming the session after passivation resulted in missing or empty data pages when using an SAP integration with Pega Cloud. This was traced to a security change that modified the D_SAMLAssertionDataPage and D_SamlSsoLoginInfo data pages as readonly, causing them to not be passivated under these conditions. To resolve this, the data pages have been made editable so they will be restored as expected. This change also resolves any difficulty with SAML logoff activities in conjunction with SAP and Pega Cloud.

SR-D37872 · Issue 507341

prproductmigration build.gradle updated for new mime4j asset name

Resolved in Pega Version 8.2.4

While running the getMigrationLog for ProductMigration script provided in the Pega 8.2.2 media files, errors appeared referencing "NoClassDefFoundErrors when running getLogs". This was caused by the referenced class not being found on the classpath: the version of the included jar did not include the class needed due to Praxiom's default version being updated to use a new version of mime4j that required an asset name change. To resolve this, the mime4j asset name in prproductmigration build.gradle has been updated to pick up the correct version of the dependency for Praxiom.

INC-174321 · Issue 664240

SSLContext created using protocol from REST connector rule form

Resolved in Pega Version 8.4.6

After upgrading to IBM websphere v9.0.5.6 or higher, API calls Like REST, Connect-HTTP etc were failing to connect to endpoints using TLSv1.2. Investigation showed that although the connector was configured to send TLSv1.2, the ClientHello handshake was triggered for TLSv1.3. Because the SSLContext was created with highest version supported by protocol in the WAS container, this has been resolved by modifying the code to create SSLContext based on the the protocol selected in the REST connector rule form. Additionally, please note that the Connect-HTTP connector has been deprecated and the Connect-REST capabilities in the platform should be used instead.

INC-184756 · Issue 667323

Static assembler correctly creates temp directory

Resolved in Pega Version 8.4.6

Static Assembly CLI was failing while creating a temp directory. This was traced to an issue with staticAssembler.xml, and has been resolved. In addition, security improvements have been added to the XML transformer.

INC-190722 · Issue 676403

Ruleset Restoration Utility repaired

Resolved in Pega Version 8.4.6

Attempting to use the standard Ruleset Restoration utility after update was resulting in a "Status:fail Operator:Unauthenticated or not available Node:No ID available" error message. This was a missed use case for the refactoring done around importing rules, and was caused by the utility calling the deprecated Importable.isValidImport() method. This has been resolved by updating the import activity to restore its functionality.

INC-163791 · Issue 704030

Simplified default reference time calculations

Resolved in Pega Version 8.8

After a job scheduler was configured to run at Start time = 21:00:00 for Time zone = Europe/London, the scheduler determined 20:00:00 as the next start time. This was due to the calculation for the next start time using the time zone offset calculation pattern for the date and time stored in System-Runtime-Context.pxCreateDateTime, which had difficulty with changes to the time zone definition implemented in the time between the given date and today (meaning the current time) such as daylight savings time. To resolve this, the default reference time from System Runtime Context will be 'now' instead of Date(0).