INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

SR-D20439 · Issue 496405

Hotfix hashmap cleanup improved

Resolved in Pega Version 8.1.7

A DL installation failed with an out-of-memory error. It was observed that many CacheEntry(VersionedJdbcJarRwader.java) hashmaps were being created to store the details for each hotfix but that were then never cleared. This has been resolved by adding the finally block in CodeImportProcessImpl.java class to call the shutdown method for proper cleanup. In addition, the default command line utility (prpcUtils) has been updated to use JVM settings of Xmx 4GB and capture a heap dump if an out-of-memory error is encountered. The auto-generated prconfig.xml has also been updated to leverage its minimal startup setting which will avoid loading the conclusion cache into memory.

SR-D28538 · Issue 502059

Corrected requestor status flag for direct map

Resolved in Pega Version 8.1.7

Numerous "Unable to create requestor" alerts were logged. This was traced to an error in HttpAPI where after retrieving the requestor from the internal requestor map directly, the requestor creation status flag was not set properly. This caused last action to post that alert instead of the correct notice of "existing requestor retrieved". This has been resolved so the flag reflects the correct status.

SR-D51554 · Issue 514064

Local UUID cache will be updated when merge event is detected

Resolved in Pega Version 8.1.7

Cluster-related issues were seen in multiple production clusters. For some nodes in the cluster the Cluster Management screen showed all expected nodes with valid Node IDs displayed, and on other nodes the Cluster Management screen showed the node ID of itself, SERVER@localhost:5701. On an impacted node displaying the wrong ID, the Node Information landing page did not work and displayed the error "Unable to execute job on ." Multiple advanced agents running on nodes in the affected clusters, both with correct and incorrect IDs, also failed with a similar error "Unable to execute job on <node's job id>". This was traced to a merge performed after a split brain. To resolve this, the code has been updated to handle merge events: when the node UUID is changed as part of a split brain recovery, the local UUID cache will be updated when the merge event is detected.

SR-D20423 · Issue 503447

Improved upgrade handling for tables using classes with property references

Resolved in Pega Version 8.1.7

After upgrade, some page property values were blank and exposed database columns did not contain the values. Investigation showed that the reference properties did not have context and hence column population was not able to determine their value. To resolve this, instead of doing column population for all the columns, the system will identify classes that have property references and that are being optimized as part of upgrade process and maintain a list of specific columns to update.

SR-D29485 · Issue 503514

Enhancement added to modify URL encryption for load testing

Resolved in Pega Version 8.1.7

An enhancement has been added which allows conditionally modifying URL encryption for load testing. This uses the flag crypto/useportablecipherforurlencryption: if true, a portable hardcoded key is used to encrypt the URLs and if false, a dynamically generated key per thread/requestor is used to encrypt the URL.

SR-D52969 · Issue 514705

Column population honors thread count of 1

Resolved in Pega Version 8.1.7

The thread count parameter in the column population activity was not being honored, causing repeated deadlocks when trying to populate columns. Investigation showed that the ExposeCols process did not honor the thread count when it was 1 (the default is 4), and this has been fixed by adding the necessary code so that if the thread count is 1, it will not run in multhreaded mode.