SR-D63668 · Issue 525478

Access Control Policy updated to handle NotEqual with valuelist

Resolved in Pega Version 8.3.2

When editing the Access Control Policy Condition rule in Designer Studio and setting condition to 'is not equal', comparing it to a list generated the error "function not found". The same configuration worked as expected for the 'is equal' condition. This has been resolved by updating policycondition to handle a not equal scenario combined with a valueList property.

SR-D63681 · Issue 527382

Localization added to login page messages

Resolved in Pega Version 8.3.2

Localization has been added to the messages that appear on the login and forgot password screens.

SR-D63727 · Issue 531723

Authorization header base 64 format error recategorized as debug logging

Resolved in Pega Version 8.3.2

Numerous messages were generated indicating that the Authorization Header format was invalid when using the format " : " (Base64 Og==) . As this is the default behavior for a particular class of proxy servers, the error statement has been updated to be logged as a debug statement and will be visible only when that logging is enabled.

SR-D64408 · Issue 530280

Stacktrace will be generated for oLog errors

Resolved in Pega Version 8.3.2

In order to provide improved diagnostics, oLog errors will print stacktraces.

SR-D66222 · Issue 529634

Tracer expiration set for five minutes

Resolved in Pega Version 8.3.2

Tracer was not terminating on tracer window closure. On the next attempt to open a trace, a message appeared stating "Cannot Launch Multiple Tracer Sessions for a requestor. This requestor is being traced by operator". Tracer session termination was dependent on the browser executing code on window close. Because this event may not be triggered for number of reasons, updates have been made to set tracer session expiration at 5 minutes. In addition, the system will clean up expired sessions before checking for existing sessions.

SR-D66521 · Issue 536138

Logout Redirect updated to handle special characters in IDP parameters

Resolved in Pega Version 8.3.2

When using "HTTP Redirect" in Authentication Service, the Logout Redirect service was failing due to the query parameter name containing "_" (underscore). This was traced to IDP sending parameters to assertion consumer service or logout request endpoint with names which contained any special characters, as the system was trying to put those key values on the parameter page for additional processing. To resolve this, the system has been updated to suppress exceptions when the parameters from IDP includes special characters.

SR-D67945 · Issue 529718

PDC JMS Listener accesses conversion of tenant hash to tenant name

Resolved in Pega Version 8.3.2

A new API method has been added for the PDC JMS listener to access getTenantNameFromTenantHash().

SR-D70569 · Issue 538507

Tracer retains modified user settings

Resolved in Pega Version 8.3.2

User settings in tracer were not shown when the settings window was closed and reopened. Investigation showed that settings are filtered based on watchInsKey, but this parameter was passed as "null" for global tracer because of a missing condition to check the session type. This has been resolved by adding a check so the WatchInsKey parameter is passed if the session type is rule watch.

SR-D71378 · Issue 533280

Authorization header base 64 format error recategorized as debug logging

Resolved in Pega Version 8.3.2

Numerous messages were generated indicating that the Authorization Header format was invalid when using the format " : " (Base64 Og==) . As this is the default behavior for a particular class of proxy servers, the error statement has been updated to be logged as a debug statement and will be visible only when that logging is enabled.

SR-D72636 · Issue 536087

Added handling for Authorization Server login loop

Resolved in Pega Version 8.3.2

When the Authorization server returned an error, it was redirecting back with error, error_description, and parameters. The system then tried to start the login process again, the same error parameters were returned again, and it continued to loop this way. To resolve this issue, handling has been added for this error scenario from the Authorization Server.