INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

INC-184798 · Issue 703269

PRconfig added for JVM user/password

Resolved in Pega Version 8.7.1

The setting Dcom.sun.management.jmxremote.local.only=true has been added for use when JMX authentication is enabled by providing jmxuser/password through prconfig.

INC-194348 · Issue 703374

Resolved multiple copies of Pega0050 alerts

Resolved in Pega Version 8.7.1

The PDC alert Pega0050 was seen multiple times for the standard pxgetoperatordetails activity, step 6.This has been fixed by removing the pagecopy and updating the data page properties.

INC-195580 · Issue 684492

Delay Factor updated to allow values < 1.0

Resolved in Pega Version 8.7.1

After modifying the "Delay factor" parameter on a queue processor rule and and clicking the "Save" button, refreshing the page caused the value of the "Delay factor" parameter to change. This has been resolved by updating the delay calculation strategy to support factors < 1.0.

INC-196478 · Issue 683130

CORS policy updated for GET streams

Resolved in Pega Version 8.7.1

CORS (Access-Control-Allow-Origin) support has been added to handle Stream calls during GET requests.

INC-163791 · Issue 704029

Simplified default reference time calculations

Resolved in Pega Version 8.7.1

After a job scheduler was configured to run at Start time = 21:00:00 for Time zone = Europe/London, the scheduler determined 20:00:00 as the next start time. This was due to the calculation for the next start time using the time zone offset calculation pattern for the date and time stored in System-Runtime-Context.pxCreateDateTime, which had difficulty with changes to the time zone definition implemented in the time between the given date and today (meaning the current time) such as daylight savings time. To resolve this, the default reference time from System Runtime Context will be 'now' instead of Date(0).

SR-D85653 · Issue 548600

Repaired Tracer use with Google Chrome

Resolved in Pega Version 8.5

After running Tracer while using Chrome, closing it and trying to run another resulted in an error indicating "Cannot Launch multiple tracer sessions for a requestor". This was identified as a bug with Google Chrome Versions greater than 70 and was caused by Chrome deprecating the use of sync XHR on page dismissal, and has been resolved by modifying the system to use a beacon API instead.

SR-D54319 · Issue 532528

API added to sync presence with requestor to clear inactive operator sessions

Resolved in Pega Version 8.5

An intermittent error message was seen indicating the maximum number of active sessions for the current operator had been reached even though there were not multiple logins and there was no requestor displayed in the requestor management landing page. This was traced to sessions that were not properly closed and cleared, and has been resolved by exposing an API that will sync the presence record with the requestor state so inactive sessions will be cleared.

SR-D64608 · Issue 544388

Corrected filedownload extension header issue

Resolved in Pega Version 8.5

Filedownload header contained plain non-ascii characters which caused a security violation issue. This has been resolved by removing the filedownload header from the HTTP response when the sendfile API is used with inputstream to download a file.