INC-167311 · Issue 646477
Updated upgrade handling for migrating work objects
Resolved in Pega Version 8.3.6
After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.
INC-172675 · Issue 649451
Configuration added for extending queue processor timeout
Resolved in Pega Version 8.3.6
Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.
INC-174321 · Issue 664240
SSLContext created using protocol from REST connector rule form
Resolved in Pega Version 8.4.6
After upgrading to IBM websphere v9.0.5.6 or higher, API calls Like REST, Connect-HTTP etc were failing to connect to endpoints using TLSv1.2. Investigation showed that although the connector was configured to send TLSv1.2, the ClientHello handshake was triggered for TLSv1.3. Because the SSLContext was created with highest version supported by protocol in the WAS container, this has been resolved by modifying the code to create SSLContext based on the the protocol selected in the REST connector rule form. Additionally, please note that the Connect-HTTP connector has been deprecated and the Connect-REST capabilities in the platform should be used instead.
INC-184756 · Issue 667323
Static assembler correctly creates temp directory
Resolved in Pega Version 8.4.6
Static Assembly CLI was failing while creating a temp directory. This was traced to an issue with staticAssembler.xml, and has been resolved. In addition, security improvements have been added to the XML transformer.
INC-190722 · Issue 676403
Ruleset Restoration Utility repaired
Resolved in Pega Version 8.4.6
Attempting to use the standard Ruleset Restoration utility after update was resulting in a "Status:fail Operator:Unauthenticated or not available Node:No ID available" error message. This was a missed use case for the refactoring done around importing rules, and was caused by the utility calling the deprecated Importable.isValidImport() method. This has been resolved by updating the import activity to restore its functionality.