Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.

INC-174321 · Issue 664240

SSLContext created using protocol from REST connector rule form

Resolved in Pega Version 8.4.6

After upgrading to IBM websphere v9.0.5.6 or higher, API calls Like REST, Connect-HTTP etc were failing to connect to endpoints using TLSv1.2. Investigation showed that although the connector was configured to send TLSv1.2, the ClientHello handshake was triggered for TLSv1.3. Because the SSLContext was created with highest version supported by protocol in the WAS container, this has been resolved by modifying the code to create SSLContext based on the the protocol selected in the REST connector rule form. Additionally, please note that the Connect-HTTP connector has been deprecated and the Connect-REST capabilities in the platform should be used instead.

INC-184756 · Issue 667323

Static assembler correctly creates temp directory

Resolved in Pega Version 8.4.6

Static Assembly CLI was failing while creating a temp directory. This was traced to an issue with staticAssembler.xml, and has been resolved. In addition, security improvements have been added to the XML transformer.

INC-190722 · Issue 676403

Ruleset Restoration Utility repaired

Resolved in Pega Version 8.4.6

Attempting to use the standard Ruleset Restoration utility after update was resulting in a "Status:fail Operator:Unauthenticated or not available Node:No ID available" error message. This was a missed use case for the refactoring done around importing rules, and was caused by the utility calling the deprecated Importable.isValidImport() method. This has been resolved by updating the import activity to restore its functionality.

INC-145293 · Issue 610933

Additional diagnostic logging added for ElasticSearch startup issues

Resolved in Pega Version 8.6.3

The PyIndexerState was stuck in Starting status during node initialization. This issue could occur if the filesystem became hung due to network level issue while scanning entries from /etc/mtab, resulting in a lock which was not released correctly. In order to better determine which node entry in a cluster may be responsible for the hang, an update has been made which will use a temporary virtual environment to repeat the part of the initialization phase responsible and generate additional logs for debugging. To activate this, the PegaSearch.Diagnostics logger must be set in DEBUG mode. This duplicated virtual initialization will not interrupt the normal initialization.

INC-153849 · Issue 641923

Updated replica management for search clusters

Resolved in Pega Version 8.6.3

When using a cluster with two Universal nodes in the cluster, a daily restart process where the second node was not started until the first was fully up resulted in Search initialization failing for the first node while becoming active on the second node. This was traced to the methods used in increasing and decreasing replicas. This has been resolved by revising the handling of ElasticSearch node lifecycle and replicas through a new option "Dindex.searchNodeCount " which includes a specification for the number of expected search nodes. If this option is not present, the old method will be used.

INC-168003 · Issue 655376

BIX Total Instance count matches manifest

Resolved in Pega Version 8.6.3

The BIX Manifest file was showing a count mismatch when the BIX Manifest and Extract files were shared with downstream teams, causing data to not be accepted by the downstream application. Investigation showed this occurred for an embedded page list property in the sequence that was missed and not considered. To resolve this, a DSS has been added: when BIX/generateAllEmptySubscriptForPageList is set to true, an empty subscript will be generated for the missed properties.

INC-178002 · Issue 663769

Restore point handling updated for absent pzpvstream column

Resolved in Pega Version 8.6.3

While executing the “get restore point” action for rollback, a PZPVSTREAMerror error occurred with the message "(util.HistoryCollectorDataModel) WARN|Rest|SystemManagement|v2|restorepoint - History collection for the table will be slow because it does not have all of the required columns". This was a missed use case for Robotics Automation not having a pzpvstream column for one of the tables; this has been corrected with a check to validate for pzpvstream column so the system will not seek history records if the pzpvstream column is not present.

INC-181941 · Issue 664807

Handling added for using virtual network interface for Stream Services startup

Resolved in Pega Version 8.6.3

After update, the restart of any node failed with the error "Unable to create DSM service DATA-DECISION-SERVICE-STREAMSERVER DEFAULT". This has been resolved by adding support for allowing stream service to start on the virtual network interface in cases where it was explicitly configured via the "cluster/hazelcast/interface".

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us