INC-218001 · Issue 719922
Error text revised for parameterized data page used for token generation
Resolved in Pega Version 8.6.5
While trying to add a claim in the header of a Token Generation Profile instance, selecting Map From as "Clipboard" and trying to give any DataPage(parameterized) as the source property failed to be saved and the error "JWS Alias— Please provide correct algorithm key with correct key length." appeared. Changing the "Map From" to a Constant and giving a dummy value worked as expected. Tracer showed the error "declare page parameters not supported by PropertyReference", indicating the actual issue: at this time, the Token profile does not support using a parameterized data page. This has been addressed by ensuring an appropriate error message is shown on save of the token profile rule form when a parameterized data page reference is configured. The error will now read "The reference D_pzPreferenceStore[PreferenceOperatorID:"[email protected]"].pxObjClass is not valid. Reason: Parameterized data page reference is not supported." Support for a parameterized data page used with Map From will be taken as an enhancement for a future release.
INC-218340 · Issue 714663
Override added to delete records for a stream dataset after processing
Resolved in Pega Version 8.6.5
Kafka data was accumulating for a Stream data set due to huge volume of inbound calls. This has been resolved by adding support to override pyDeletedProcessed through a DASS in order to remove the records for a particular stream dataset (topic) as soon as they are processed by Pega.
INC-218909 · Issue 715282
Override added to delete records for a stream dataset after processing
Resolved in Pega Version 8.6.5
Kafka data was accumulating for a Stream data set due to huge volume of inbound calls. This has been resolved by adding support to override pyDeletedProcessed through a DASS in order to remove the records for a particular stream dataset (topic) as soon as they are processed by Pega.
INC-219566 · Issue 721290
Handling updated for CSRF in queue processor trace
Resolved in Pega Version 8.6.5
The field level audit on properties was intermittently not being shown on the Audit history table for the first time for some users. This has been resolved by modifying the queue processor trace to better handle CSRF tokens.
INC-225519 · Issue 724398
Improved handling for thread resolution issues
Resolved in Pega Version 8.6.5
Queue Processor/Dataflow was moving to STOPPED state due to failed records in its execution. Investigation showed there was a minor logic issue in the queue processor activity which allowed the Page-Remove step to be called even before the pages were actually created, and this has been resolved by improving the recovery from a cleared ThreadContainer which might cause thread resolution issues.
SR-B65434 · Issue 334578
Oracle table metadata performance improvements
Resolved in Pega Version 7.4
Performance improvements have been added for Oracle table metadata queries.
SR-B74189 · Issue 334576
Oracle table metadata performance improvements
Resolved in Pega Version 7.4
Performance improvements have been added for Oracle table metadata queries.
SR-B76468 · Issue 336009
Oracle table metadata performance improvements
Resolved in Pega Version 7.4
Performance improvements have been added for Oracle table metadata queries.
SR-B76989 · Issue 327639
Informational text added to "No suitable driver" error message
Resolved in Pega Version 7.4
After configuring Pega to connect to an external database using Data-Admin-DB-Name with a JDBC URL configuration that had the appropriate jar for the driver in the application server classpath, unexpected behaviors were seen. The first time the Test Connectivity button was clicked, a "No suitable driver found" error appeared. The second click ran the test as expected. This confusion was related to an undocumented enhancement: because adding a new database JDBC driver in Pega may require configuration to get the driver class loaded to the classpath, the 'No suitable driver' exception was enhanced with the configuration required to get the JDBC driver loaded at the next restart. In order to avoid confusion, informational text will now appear as part of the "No suitable driver" error message to explain this.
SR-B82933 · Issue 333921
SQL queries constructed to stay below 1000 limit
Resolved in Pega Version 7.4
A very large SQL query referencing a large number of history classes was generating an SQL syntax error exception due to exceeding the maximum number of expressions in a list (1000). In order to support large queries, the SystemManagementUtils.generateWhereINClause function will now construct queries that stay below that limit per single query.