INC-162360 · Issue 635817
Unneeded AUC error percentage calculation removed for better system performance
Resolved in Pega Version 8.6
When generating snapshots of the ADM models, an inefficiency in the metric calculation for the AUC error percentage caused an excessive amount of memory to be allocated which could cause slowdown or require a system reboot. This has been resolved by removing the problematic AUC error percentage calculation as it is not used in the UI.
INC-163940 · Issue 634491
CustomerData schema added to list of databases for optimization
Resolved in Pega Version 8.6
was no "Create?" column. This column appeared for the PegaDATA database but not for CustomerData. To resolve this, the Optimize Schema Landing Page has been updated to treat the CustomerData schema as a shipped Pega database.
INC-167311 · Issue 646477
Updated upgrade handling for migrating work objects
Resolved in Pega Version 8.3.6
After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.
INC-172675 · Issue 649451
Configuration added for extending queue processor timeout
Resolved in Pega Version 8.3.6
Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.