INC-155789 · Issue 622546

Third-party libraries upgraded

Resolved in Pega Version 8.5.3

The following third-party jar files have been updated to the most recent versions:ant: v1.10.9 httpclient: v4.5.13 xercesImpl: v2.12.1

INC-157196 · Issue 629298

Deprecated service package features now require authentication

Resolved in Pega Version 8.5.3

Authentication has been added to deprecated features of the standard service package to improve security. If issues are encountered during product migration, please use the Deployment Manager.

INC-158519 · Issue 625080

Filter considers all instances pages during deployment

Resolved in Pega Version 8.5.3

During package deployment, attempting to use Filter to skip some of the instances only displayed the result of the current active page instead of all pages. This was an unintended consequence of previous work, and has been resolved by adding the logic to strip quotes in the value and adding the "Pagination activity manages filtering" checkbox by default.

INC-160288 · Issue 626068

Kerberos handling updated for database remap

Resolved in Pega Version 8.5.3

After upgrade from Pega v7.2 to Pega v8.4, using Kerberos authentication was failing during the remap task. Investigation showed that null username and password values were being passed to SchemaAssignmentUtility along with the flags as arguments, causing the utility to misinterpret the arguments. As arguments should be populated only when flags and values are available and not null, an update has been made which will set the username and password flags only if they are not null in the Remap database tables target.

INC-167311 · Issue 646477

Updated upgrade handling for migrating work objects

Resolved in Pega Version 8.3.6

After upgrading from Pega 6.2 to 8.3, the work migrated work objects were missing SLAs due to missed entries in the assignment tables (PC_ASSIGN_WORKLIST/ PC_ASSIGN_WORKBASKET) . The SLA was firing, but the processing failed due to the fact the runtime could not resolve a 'AddHistoryPage' library function. In this case, multiple upgrades of the application dating back to Pega 4 resulted in the runtime context containing older ruleset versions in higher ruleset versions, hiding the underlying Pega 8 version of the rule. For releases prior to Pega 7.3, Rule-Application was stored in pr4_rule and will be migrated to pr4_rule_application during upgrades. However, since Context Upgrade is run before Optimize Newly Exposed Columns, the pyDependsOnName won't always be populated. To resolve this, the system will filter based on the value in the blob rather than the exposed column so there will be a value regardless of the upgrade-from version.

INC-172675 · Issue 649451

Configuration added for extending queue processor timeout

Resolved in Pega Version 8.3.6

Alerts for queue processor (QP) items which took more than 15 minutes to run could result in the system marking the node as 'unhealthy'. In environments with Pega Health Check enabled, this would shut down the node gracefully. It was not possible to change this default as it was hardcoded. In order to support systems that may have custom processes that run beyond 15 minutes, a a new setting has been exposed that allows configuration of the interval after which a node with long-running queue processor is marked as unhealthy and is restarted. By default this remains 900000 milliseconds / 900 seconds / 15 minutes, but it may be adjusted up to 24 hours to avoid premature node shutdown. The stale thread detection mechanism will take that setting into account and use the provided value or default to 15 minutes if the value was not provided. In addition, the threshold's units in the UI have been changed from ms to seconds.