Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-117674 · Issue 170571

Smart Shapes use properly limited to work class

Resolved in Pega Version 7.1.7

An error in the code made Smart Shapes visible when creating a data-class flow. Attempting to include them by dragging them into the flow design pane resulted in an "empty" utility shape that was missing many of the options normally offered. Because Smart Shapes are designed only for work classes, Smart Shapes will not be visible in shape menu when a flow is created in data class.

SR-117744 · Issue 172508

BodyVisibleWhen updated for repeating tab layouts

Resolved in Pega Version 7.1.7

Previously, repeating tabbed layouts had the option of BodyVisibleWhen in the properties of the layout for referring to a 'when' condition of the pagelist property. After migration, attempting to use the 'when' condition took the class of the section and not the class of the pagelist. The ValidateSection and its includes have been modified to properly consider the tabbed/column repeat 'when' condition validation.

SR-117752 · Issue 171493

Changed decimal values to comma values for NL/SE localization

Resolved in Pega Version 7.1.7

The Dutch and Swedish convention for decimals is to use a comma as the separator instead of a dot. This use was not included in the localization so clicking on submit caused the comma values to be converted with a decimal point that multiplied the value by 100. (1200,00 is twelve hundred euros; the value became 120,000.00 - one hundred and twenty thousand euros) This has been fixed so the values are correctly handled with commas when localized to NL or SE.

SR-119243 · Issue 175219

Changed decimal values to comma values for NL/SE localization

Resolved in Pega Version 7.1.7

The Dutch and Swedish convention for decimals is to use a comma as the separator instead of a dot. This use was not included in the localization so clicking on submit caused the comma values to be converted with a decimal point that multiplied the value by 100. (1200,00 is twelve hundred euros; the value became 120,000.00 - one hundred and twenty thousand euros) This has been fixed so the values are correctly handled with commas when localized to NL or SE.

SR-117805 · Issue 173117

Corrected IE handling of date picker in Report Definition custom sections

Resolved in Pega Version 7.1.7

A report definition configured to use a custom section for filtering caused a JS error in IE browsers when selecting dates from the date picker multiple times. In IE only, the DOM object containing the popup is removed from the DOM after refreshing, but the reference, _container, is not nulled. As a result, IE was trying to reuse a DOM object that wasn't present on the screen. This has been corrected.

SR-117844 · Issue 170991

Auto-refresh only available for Section Tabs

Resolved in Pega Version 7.1.7

When the "Refresh when active" checkbox was checked in a harness used in the Case Manager dashboard, creating or closing a WO did not update this page automatically. This is because auto-refresh is unsupported in the harness; it is better to use Section Tabs (the best practice statement explains why) and they are encouraged over using Harness tabs. In order to make this use clear, the auto-refresh checkbox will not be displayed in harness tabs.

SR-117923 · Issue 171578

Remedied spurious size alert from the attachments viewer

Resolved in Pega Version 7.1.7

When listing attachments from History & Attachment display, the work object was re-read for each attachment. If the work object had many attachments, the alert "PEGA0004 alert (50MB DB threshold)" would appear regardless of the actual attachments' size. This has been adjusted so the RUF attachment access makes use of the existing WorkPage instead of re-reading it from the database.

SR-118016 · Issue 174520

Spellcheck on text area fixed for IE8

Resolved in Pega Version 7.1.7

Using IE8, a text area with SpellCheck enabled generates the error "Script Error: Message: 'null' is null or not an object" if there is more than one line present. This was caused by the handling of the check for list length, and has been modified to work with all browsers.

SR-118053 · Issue 172515

Added edit format for Designer Studio integer control in read-only when

Resolved in Pega Version 7.1.7

In the Integer Control for Designer Studio, it is not possible to set properties on the Edit Format when the presentation is ReadOnly based on a when rule. Both the Formats appear when the Edit Options is selected as Auto. Options have now been added to set the properties.

SR-118061 · Issue 175102

CorrNew activity can send email in sync or batch

Resolved in Pega Version 7.1.7

When attempting to send email correspondence in synchronous mode i.e. not via the agent processing, the activity always queued it to the agent even when the Activity CorrNew SendNow param was set to true. To correct this, the system will pass the value of a BatchSend param based on the value of the SendNow param: email will be sent immediately If SendNow is set to 'yes', or will be queued for batch processing if SendNow is set to 'no'.