Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please update your bookmarks. This site will be discontinued in Dec 2024.

Pega Platform Resolved Issues for 8.1 and newer are now available on the Support Center.

INC-224446 · Issue 724369

Load more works in non-templatized layout

Resolved in Pega Version 8.6.5

After adding a repeating dynamic layout inside a tab group layout (which is a deprecated feature) to make it non-templatized, the progressive pagination option to show the "load more" button did not work. This was caused by the load more functionality having a dependency on pega.ui.RDL even though pega.ui.RDL was not available in case of a non-templatized grid, with the result of generating an exception which broke the flow. This has been resolved by adding a null check which will allow the flow to proceed whether the grid is used inside non-auto-generated or auto-generated elements. Please note that it is strongly recommend to update any deprecated layouts to Layout Group as it is a best practice to keep the code updated to avoid any compatibility issues.

INC-217655 · Issue 723565

Resolved validation check freeze for Dynamic Layout Group

Resolved in Pega Version 8.7.3

After creating a multi-step form where step 1 had a Dynamic Layout Group(tabbed) that used form fields configured with validations, clicking next with empty/invalid values in the form intermittently caused the screen to freeze and a javascript exception was logged. This was traced to a missed use case related to templates in the childNode, and has been resolved by adding the necessary safe checks in lgtemplate and lgcelltemplate.

INC-218855 · Issue 718834

DSS added to control section collapse on refresh

Resolved in Pega Version 8.7.3

After update from 8.5, using dynamic layouts that included certain controls (autocomplete/text/dropdown) configured with Refresh-Other Section -> Parent / Top Level Section such as a pyCaseActionArea with Event 'On Change' showed a different behavior: entering a value in the configured text/auto-complete field that leads to the refresh of the top level section will collapse all expanded sections if there is a refresh trigger within the embedded section or dynamic layout of the collapsible layouts. In order to control this behavior, a new DSS has been introduced. By default HonourExpandWhenOnRefresh (owning ruleset Pega-UIEngine) will be set to false to maintain the current behavior of collapse on refresh, while setting it to true will use the older behavior of maintaining expanded sections.

INC-223222 · Issue 723634

Corrected apiContext when using bulkActions

Resolved in Pega Version 8.7.3

Row selections in the multi-selection table were intermittently not working after opening a table with bulk actions enabled. Investigation showed that opening a table with bulkActions enabled and then navigating to a table where bulk actions are not available but multi-select is enabled led to functions like setSelectedRows and getSelectedRows still being available in apiContext. This has been resolved by correcting apiContext when bulkActions is enabled.

INC-225236 · Issue 725703

Corrected LiveDesignViewDisplay error handling

Resolved in Pega Version 8.7.3

When all rulesets were locked and a section was opened from Live UI in a portal, a "rule deleted" message appeared and it was confirmed the rule was deleted even though the rule was in locked ruleset. Investigation traced this to a pzLiveDesignViewDisplay call to pxChooseBestRuleSet which jumped to failure logic when "allow check out" was disabled, and this has been resolved by correcting the error handling in pzLiveDesignViewDisplay.

INC-188469 · Issue 714843

Updated retainLock for DoClose activity

Resolved in Pega Version 8.8

After sending an external email notification from a case, attempting to use the "close" button resulted in an access denied error. This was traced to a missed use case for recent security improvements which resulted in not setting the required parameter retainLock for the DoClose activity, and has been resolved.

INC-192673 · Issue 689552

Tab highlighting updated

Resolved in Pega Version 8.8

Not all elements were indicated with yellow highlighting when tabbing through the screen. This has been resolved.

INC-194180 · Issue 704636

GetChildcases handling updated for large numbers of cases

Resolved in Pega Version 8.8

When a very high number of child cases being processed contained a wait shape that was dependent on the movement of a parent case, some of the cases were moved to the next step of the flow automatically while others required a manual command to ResumeFlow. In extreme cases where many child cases were waiting, a node crash could occur. This was traced to the pzGetChildcases report having a maximum value of 500 lines, and has been resolved by increasing the maximum number of rows to retrieve to 9999 in the Data Access Tab of the pzGetChildCases report definition. In addition, the pxCheckFlowDependencies activity has been modified to perform with a higher number of cases, and DSS(MaxRecords) logic has been added to split the child cases into multiple queue items for each access group to decrease load on each thread process.

INC-201723 · Issue 719854

Audit message displays correct parameter value

Resolved in Pega Version 8.8

The Audit message showed "{1}" instead of displaying the parameter value dynamically. This was traced to the pyInstructions field value which contained the message "Please approve or reject this {1}", and has been resolved by updating the pzInstructionsForApproval rule so the correct value is displayed.

INC-203595 · Issue 702360

Updated retainLock for DoClose activity

Resolved in Pega Version 8.8

After sending an external email notification from a case, attempting to use the "close" button resulted in an access denied error. This was traced to a missed use case for recent security improvements which resulted in not setting the required parameter retainLock for the DoClose activity, and has been resolved.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us