SR-D33359 · Issue 505773

SelectAll properly applied to only the page selected

Resolved in Pega Version 8.2.4

In repeating grid, applying SelectAll on one page resulted in it being applied to the next page as well even though all records in the other page were not selected. Investigation showed that on change, the 'when' condition added to refresh the list was always false. To resolve this, the condition in section pzBulkProcessingCheckbox which refreshes the list once the checkbox is changed has been removed.

SR-D37444 · Issue 507038

WorkBasketGadget control updated for improved backwards compatibility

Resolved in Pega Version 8.2.4

After upgrade, the WorkBasketGadget Control was not retrieving the work queues. This was traced to a backwards compatibility issue introduced when greater security was put in place. The control WorkBasketGadget contains a call to pzEncryptURLActionString that was introduced in 8.x versions of the platform to encrypt URLs to avoid hijacking. The content of the URL relies on the pxRequestor.pxWorkGroup property, which is resolved using pega:reference tags. This approach was working in versions below 8.x, but these tags were not resolved at runtime. To correct this, requestorWorkGroup will be resolved as string and passed as a parameter instead of using pega:reference tags.

SR-D26785 · Issue 495892

Corrected error when persisting temporary work object

Resolved in Pega Version 8.2.4

When persisting a temporary work object using the Persist case shape, the internal assignment handle was not updated to include the work object's ID. Subsequent attempts to access the internal assignment (such as the "Edit" button on the Review Harness) resulted in errors. Investigation showed that when a temporary case was persisted, pyInternalAssignmentHandle was not getting recalculated after pzInsKey was updated. To resolve this, the configuration on the edit button has been modified to use .pxFlow(pzInternalCaseFlow).pxAssignmentKey which is what pyInternalAssignmentHandle declare expression was also returning.

SR-D32525 · Issue 505467

Dirty check added to offer save/discard changes when closing tab

Resolved in Pega Version 8.2.4

With the OOTB section enabled, performing a change in the form (changing a text value, selecting a option in a dropdown, etc.) and closing the case generated an unexpected alert indicating that the case was changed and the modifications were lost. This differs from the previous behavior of showing the section pyDirtyCheckConfirm which offered the opportunity to save the work. This was a missed use case and has been resolved by updating the system to perform a check for the dirty state when closing the interaction and show a modal dialog asking the user to choose either save/discard if dirty.

SR-D29832 · Issue 503225

Corrected image alignment for email case creation

Resolved in Pega Version 8.2.4

An issue with missing image styling when an email was sent to create a case was traced to the Owasp library stripping align attributes from the img tag. This has been fixed.

SR-D33966 · Issue 504607

Corrected accessibility error after resize

Resolved in Pega Version 8.2.4

From within a Case and on a screen displaying the Information and Audit tabs in a Layout group, it was possible to use a series of sequences that included resizing the browser and opening Audit to cause the information tab to no longer be accessible. This has been resolved by setting the transform value to 0 after completing the resize.

SR-D47018 · Issue 517032

Corrected parameter being encrypted during change portal configuration

Resolved in Pega Version 8.2.5

After configuring a changePortalLayout control using .pyDescription as property, trying to switch the portal was throwing a error page. The same configuration worked in earlier platform versions. This was traced to recent updates where the activity parameter ended up being encrypted along with the activity name, and has been resolved by removing the parameter from encryption input and adding it to encryption output.

SR-D5904 · Issue 511600

Discard changes dialog now showing for local actions

Resolved in Pega Version 8.2.5

After having modified case data without saving and clicking on a menu entry (left menu, search, ...), the system shows a dialog box to ask the user to confirm it is ok to discard changes. However, this confirmation dialog did not work with local actions, leading users to lose their work without any warning nor any way to step back. This was traced to a difference in the dirty form check, which was not present when launching a local action from a case. An enhancement has now been added to the handleMenuAction js function in pypega_ui_harnessactions.js which will perform a dirty form check with a prompt.

SR-D39264 · Issue 518840

Multiple files uploaded using "select file" will be handled asynchronously

Resolved in Pega Version 8.2.6

In order to resolve an intermittent error when uploading multiple files using the "select file" button, each file will be uploaded asynchronously to avoid overloading the browser threshold.

SR-D47146 · Issue 515648

Pick Values modal updated for deprecated list view handling

Resolved in Pega Version 8.2.6

Pick values were not displaying in the menus below Case Management-> Tools -> My Work, including "Work entered by me", "Work by workbasket", and "Work resolved by me recently". This was due to the use of deprecated list views: the pick values modal was failing to show and hide the busy indicator because the indicator now uses jQuery, but list view does not include jQuery. In order to resolve this, the equivalent Report Definition pyEnteredByMe has now been added under the navigation rule : pzProcessAndCaseRulesMainMenu.