SR-D76291 · Issue 547843
Updated retry logic for S3 AddAttachmentFromEmail
Resolved in Pega Version 8.4.1
When using the AddAttachmentFromEmail activity with S3 repositories, performing an obj-save on the data-workattach-file page executes a deferred save while also saving the file into the repository. if the data was inserted into S3 successfully but encountered an issue when saving the related data-work-attach-file page, the system was trying to call the save operation again. This tried to insert the duplicate attachment again to S3, causing an error on that side of the process. To resolve this, the duplicate Obj-Save functionality in AddAttachmentFromMail Activity has been removed.
SR-D79113 · Issue 543723
Updated DisplayAttachment to handle SIngleClick download from Case Worker portal
Resolved in Pega Version 8.4.1
On using the script "pega.ui.HarnessActions.doAttachmentSingleClick" in the Worker portal to download attachments displayed within a screen flow, the entire application was hanging and no action was invoked even on clicking the Continue or Finish buttons of the screen flow. Whenever an attachment is downloaded using the script function pega.ui.HarnessActions.doAttachmentSingleClick() , an iframe is used and changetracker is called to communicate data between different iframes. However, the case worker portal is a single thread model while the manager and admin portals are multi threaded, which resulted in changetracker freezing on the worker portal. To resolve this, the DisplayAttachment HTML rule has been updated to build the necessary changeTrackerMap for the worker portal.
SR-D84480 · Issue 546189
FilterHistory decision tree used for audit log status
Resolved in Pega Version 8.4.1
Attempting to use the “FilterHistory” decision tree in the work class to return value “false” for “pyCloseOpenAssignmentsOnResolution” to hide the “pyCloseOpenAssignmentsOnResolution” field value (“Unfinished assignments were cleaned up by the system after the completion.. ”) from history was not working as expected, and still returned the audit message. This was due to the system setting this AuditNote parameter within the “pzProcessResolutionStage” activity, where Param.UpdateHistory was set to true always. In order to support more flexibility, the Param.updateHistory paramter in step3 of the pzProcessResolutionStage activity will be set based on the FilterHistory decision tree. When set to false in FilterHistory decision tree, pyCloseOpenAssignmentsOnResolution will be set as false and audit will not be logged.
SR-D84754 · Issue 548165
Resolved erroneous problem assignment error
Resolved in Pega Version 8.4.1
If a user processed a work item while the SLA agent was also attempting to process it, it sometimes resulted in an assignment with the error: "Error: Flow Not At Task." In this scenario, an error message was displayed stating that "Assignment already completed" even though the assignment was not yet finished, causing confusion. Investigation showed that in cases where the success indicator was -28, the assignment was marked as problem assignment even though it was processed. To resolve this, the system has been updated to skip marking the assignment as a problem when the success indicator is -28.
SR-D88141 · Issue 550010
TemplateButton field correctly set read-only
Resolved in Pega Version 8.4.1
When a control was added to a section using the DX API, a pyTemplateButton field was added to the XML definition of the section with read-only set to 'false'. This has been corrected so the pyTemplate Button field does not allow input.
INC-121435 · Issue 563875
Handling added for null requiredskillcount on assignment
Resolved in Pega Version 8.2.7
If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.
INC-122149 · Issue 562783
Corrected approval step task message
Resolved in Pega Version 8.2.7
When a case progressed to the approval step, the task name did not properly appear as part of the "Please approve or reject this" message. In another scenario, a portal which supported locale switching was not translating "Please approve or reject this" when the locale was switched, but instead displayed the message in the original language. Investigation traced this to the pzInstructionsForApproval data transform storing the localized field value, causing it to persist inappropriately. This has been resolved.
INC-127077 · Issue 564107
Busy indicator appears when uploading via Select
Resolved in Pega Version 8.2.7
After update, the “loading symbol” (busy indicator) was not appearing while uploading large attachments using the Select button. This was a missed use case in recent changes to related to AsyncUpload, and has been resolved.
SR-D76291 · Issue 547840
Updated retry logic for S3 AddAttachmentFromEmail
Resolved in Pega Version 8.2.7
When using the AddAttachmentFromEmail activity with S3 repositories, performing an obj-save on the data-workattach-file page executes a deferred save while also saving the file into the repository. if the data was inserted into S3 successfully but encountered an issue when saving the related data-work-attach-file page, the system was trying to call the save operation again. This tried to insert the duplicate attachment again to S3, causing an error on that side of the process. To resolve this, the duplicate Obj-Save functionality in AddAttachmentFromMail Activity has been removed.
SR-D92352 · Issue 553616
Completed onChange will reset FileInput value to null
Resolved in Pega Version 8.2.7
When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange. To resolve this, the value of FileInput in pzMultiFilePath Control will be set to null at the end of the onChange event so that an onChange event will be triggered next time even if the same file is added.